蒸发式冷凝器运行特点
1055 kW 氨(R-717)制冷系统湿热蒸汽节能
功率消耗压缩机= 238.6 kW冷凝器风机= 15.0 kW喷淋水泵=4.0 kW257.6 kWkWc=257.6 kW _0.88 马达机械效率风机15KW1248KPa空气空气喷淋水泵4KW储氨器压缩机238.6KWkWc= 292.7kWWorldwide Leader in Industrial and Commercial Cooling Equipment冷却塔加壳管式冷凝器系统
1055 kW 氨(R-717)制冷系统湿热蒸汽风机15KW空气空气35 C功率消耗压缩机= 280.3 kW冷却塔风机= 15.0 kW喷淋水泵=15.0 kW310.3 kWkWT=230KPa29.4 C310.3 kW _0.88 马达机械效率壳管式冷凝器1480KPa40.6 C STD11 C 吸气kWT= 352.4kW压缩机水泵15KW储氨器280.1KWWorldwide Leader in Industrial and Commercial Cooling Equipment蒸发式冷凝器运行特点----节能
采用蒸发式冷凝器的节能平均每年可节能= (kWT-kWC) (小时/年x 负荷系数)=(352.4 kW -292.7 kW) (8,760 小时x .65 系数)= 339,932 kW*小时
平均每年可节约= (节电kW*小时) (电价)=339,932 * .65=¥220,956
?生产过程中有一定的存储* 负荷系数= 65%?季节变化有一定的影响是基于以下情况选取的?每周五天工作制,每天两班Worldwide Leader in Industrial and Commercial Cooling Equipment蒸发式冷凝器设计特点
高效脱水器
?飘逸率小于循环水量的0.001% ?PVC结构抗腐蚀Worldwide Leader in Industrial and Commercial Cooling Equipment