VBOXÆû³µÕû³µÐÔÄܲâÊÔϵͳ ¹ãÖÝÔó¶û»úµç¿Æ¼¼ÓÐÏÞ¹«Ë¾
5. Á¦¾Ø·Å´óÆ÷ÐͺÅTA-3883 Á¦¾Ø²âÁ¿/torque ÊäÈë/ Input ÄÚÖÃÁ¦¾Ø´«¸ÐÆ÷£¬Ô¤·Å´óÆ÷Êä³ö0£¡À2V/0-¡À50N.m Torque sensor built-in type pre-amplifier output,0~¡À2V/0~¡À50N.m Ö±Á÷12V/ DC12V 0~¡À50N.m/0~¡À50N.m ½«ÐýÅ¥Ìøµ½×î´óλÖÃʱΪ0~¡À10V 0~¡À10V at span adjuster MAX time ×Ô¶¯µ÷Á㣬Îó²îСÓÚ1mV Auto zero adjust system, error less than 1mV 0µ½×î´óÁ¬Ðø¿Éµ÷ Continuously variable from zero to Max. 3¸ö·¶Î§£¬50N.m,20N.m,ºÍ 8N.m Three (3) steps:50N.m,20N.m,and 8N.m 2¸öÊý×Ö¿ª¹Ø£¬Ð£×¼´ø¿í1-50N.m 2006. digit digital switch calibrator, calibration band:1-50N.m 500Hz 0.02%F.S Áã¶È±ä»¯0.02%¡æ/Zero change 0.02%¡æ 3λÊý×ÖÏÔʾµ¥Ôª£¬×î´óÏÔʾ¡À99.9N.m 3 digit digital display unit MAX display¡À99.9N.m µ±Á¦¾Ø³¬¹ý51 N.mµÄʱºòÉùÒô±¨¾¯ Buzzer alarm system at more than torque 51N.m Ê©¼Óµçѹ/Added voltage ²âÊÔ·¶Î§/Measuring range Êä³öµçѹ /Output voltage Áãµãµ÷½ÚÆ÷ /Zero adjuster ÐýÅ¥ /Span adjuster É趨Á¿³Ì·¶Î§ /Range set, unit У׼ /calibration ƵÂÊÏìÓ¦´ø¿í Frequency response band ·ÇÏßÐÔ¶È/Non-linearity ÈÈϵÊý/Temperature effect ÏÔʾµ¥Ôª /Display unit ¹ýÔØÉ趨µ¥Ôª /Over load set unit. - 25 -
VBOXÆû³µÕû³µÐÔÄܲâÊÔϵͳ ¹ãÖÝÔó¶û»úµç¿Æ¼¼ÓÐÏÞ¹«Ë¾
6. ½Ç¶È²âÊÔµ¥Î»/Angle measuring unit ÊäÈë Input Ê©¼Óµçѹ/Added voltage ²âÁ¿·¶Î§/Measureing range ·Ö±æÂÊ Resolving power(resolution) Êä³öµçѹ Output voltage Áãλ¸´Î» Zero reset ÐýÅ¥µ÷½Ú Span adjuster Á¿³ÌÉ趨 Range set. Unit У׼ Calibrator À´×Ô±àÂëÆ÷µÄÂö³åÊäÈ루9000P/R£©A ÏàºÍBÏà Pulse input from encoder(9000P/R A and B phase DC5V ¡À5% 0~¡À1440¶È/0~¡À1440deg 0.01¶È/0.01degree ÔÚÐýÅ¥µ÷µ½×î´óλʱΪ0~¡À10V 0~¡À10V at span adjuster MAX time ÔÚ²Ù×÷λʱ¿ÉÒÔ½øÐÐÁãλ¸´Î» Possible to zero reset at optional position ´ÓÁãµ½×î´óÖµÁ¬Ðø¿Éµ÷ Continuously variable from zero to Max 3¸ö£¬1440£¬360ºÍ90¶È 3 steps:1440,360 and 90 deg. ½Ç¶Èͨ¹ý4¸öÊý×Ö¿ª¹Ø½øÐÐУ׼£¬ У׼·¶Î§Îª1440¶È Angle calibration by 4 digit digital switch calibration band 1 to 1440 deg. 500Hz СÓÚ0.5¶È/Less than 0.5 deg Áã¶È±ä»¯0.02%/¡æ£¬ÁéÃô¶È±ä»¯£º0.02%/¡æ Zero change 0.02%/¡æ Sensitivity change: 0.02%/¡æ 5 1/2λÊý×ÖÏÔʾµ¥Ôª£¬×î´óÏÔʾ¡À1990.99µ¥Ôª 5 1/2 digit digital display unit Max display ¡À1990.99degree ƵÂÊÏìÓ¦´ø¿í Frequency response band ·ÇÏßÐÔ/Non-linearity ζÈϵÊý Temperature effect ÏÔʾ Display - 26 -
VBOXÆû³µÕû³µÐÔÄܲâÊÔϵͳ ¹ãÖÝÔó¶û»úµç¿Æ¼¼ÓÐÏÞ¹«Ë¾
7. ½ÇËٶȲâÊÔµ¥Ôª/Angle speed measuring unit ÊäÈë input ²âÁ¿·¶Î§/Measuring range Êä³öµçѹ Output voltage ÐýÅ¥µ÷½Ú Span adjuster Á¿³ÌÉèÖà Range set unit У׼ calibrator ƵÂÊÏìÓ¦·¶Î§ Frequency response band ·ÇÏßÐÔ/Non-linearity ζÈϵÊý Temperature effect ÏÔʾÆ÷ Display ¹¤×÷ζȷ¶Î§ Operating temperature band ´æ´¢Î¶È/Stored temperature
´Ó±àÂëÆ÷ÖÐ9000P/RÊäÈë 9000P/R input from encoder 0~¡À1000¶È/Ãë/0~¡À1000degree/sec. µ±ÐýÅ¥µ÷µ½×î´óֵʱΪ0~¡À10V 0~¡À10V at span adjuster at Max time ´ÓÁãµ½×î´óÖµÁ¬Ðø¿Éµ÷ Continuously variable from 0 to Max 3¸ö£º1000¶È/Ã룬360¶È/Ã룬ºÍ180¶È/Ãë3steps:1000degree/sec.360degree/sec. and180 degree/sec. ͨ¹ý3¸öÊý×Ö¿ª¹Ø½øÐнÇËÙ¶ÈУ׼£¬Ð£×¼·¶Î§Îª10£1000¶È/Ãë / Angle speed calibration by 3 digit digital switch, calibration band 10-1000deg/sec. 500Hz СÓÚ0.02%,F.S /Less than 0.02%,F.S Áã¶È±ä»¯0.02%/¡æ£¬ÁéÃô¶È±ä»¯£º0.02%/¡æ Zero change 0.02%/¡æ Sensitivity change: 0.02%/¡æ 3 1/2λÊý×ÖÏÔʾµ¥Ôª£¬×î´óÏÔʾ¡À1000¶È/Ãë 3 1/2 digit digital display unit Max, display ¡À1000degree/sec. 0~50 ¡æ, -20-70¡æ - 27 -
VBOXÆû³µÕû³µÐÔÄܲâÊÔϵͳ ¹ãÖÝÔó¶û»úµç¿Æ¼¼ÓÐÏÞ¹«Ë¾
5. ѹ Á¦ ´« ¸Ð Æ÷¡ª¡ªPF110ϵÁÐ
* ΢ÐÍ´«¸ÐÆ÷ * 5VÄÚÖõçѹ
* ·Ç³£ÊʺϳµÉÏʹÓà * ¸ßEMI/RFI±£»¤
¿ÉÑ¡»úеÂÝÎÆ£º *M10*1 ÍâÂÝÎÆ *M 8*1 ÍâÂÝÎÆ
*3/8-24 UNF 3AÍâÂÝÎÆ
¿ÉÓûúеÁ¬½Ó£º *ÌØ·úÂÚµçÀ - 28 -