Maxwell»ù´¡½Ì³Ì·ÂÕæÊµÀý - ͼÎÄ

ÔÚPost Processing×Ӳ˵¥Ï£¬TurnsÀ¸ÖÐÈ«²¿¸ÄΪ15 Ñ¡ÖÐPhaseA_1, PhaseA_2, PhaseA_3 µã»÷°´¼ü£ºGroup -> ½«GroupÃû¸ÄΪPhaseA

Ñ¡ÖÐPhaseB_1, PhaseB_2, PhaseB_3 µã»÷°´¼ü£ºGroup -> ½«GroupÃû¸ÄΪPhaseB

Ñ¡ÖÐPhaseC_1, PhaseC_2, PhaseC_3 µã»÷°´¼ü£ºGroup -> ½«GroupÃû¸ÄΪPhaseC BranchesÈ«²¿¸ÄΪ3 ÈçÏÂͼËùʾ£º

ÿ¸öÏßȦÓÐ15ÔÑ£¬ÔÚͬһ¸öÖùÉϵÄ3¸öÏßȦÊÇ´®ÁªÁ¬½Ó¡£

5. Check & Run

6. ²é¿´½á¹û

Parameters > Matrix>(µã»÷ÓÒ¼ü)Ñ¡Ôñ£ºView Solution

¼ÌÐø·ÂÕæ£¨¸ù¾ÝÄ£Ð͵ĶԳÆÌصãÖØÐ½¨Ä££©

1.´´½¨¶Ô³ÆÄ£ÐÍ

ÓÒ¼üµã»÷Project Manager´°¿ÚÖеÄMaxwellDesign1 Copy

ÓÒ¼üµã»÷Project Manager´°¿ÚÖеÄinductance Paste

¿½±´ÁËÔ­¹¤³Ì

Ctrl+AÑ¡ÖÐËùÓÐÎïÌå

½«Ô­Ä£ÐÍÒÔYZÆ½ÃæÎª¶Ô³ÆÃæÅü¿ª£¬±£ÁôXÖáÕý°ëÖáµÄ²¿·Ö¡£ Modeler > Boolean > Split£¨·Ö¸î£© Split Plane : YZ

Keep Fragments: Positive side Split Objects: Split entire selection

2.Ð޸ļÆËãÇøÓò Draw > Region +X: 800 -X: 0

3.ÉèÖü¤Àø

½«Ä£ÐÍÐýתµ½SplitÃæ³¯Íâ

°´¡°f¡±¼ü£¬Çл»Ñ¡Ôñ·½Ê½Îª£ºÃæÑ¡Ôñ Ñ¡ÖÐ×îÓұߵÄÏßȦ½ØÃæ

Maxwell > Excitations > Assign > Current

Base Name: PhaseA_in Value: -0.5*Mag Type: Stranded

Ñ¡ÖÐ×îÓÒ±ßÏßȦµÄÁíÒ»½ØÃ棺

Maxwell > Excitations > Assign > Current Base Name: PhaseA_out Value: -0.5*Mag Type: Stranded

µã»÷ Swap£¨½»»»£©£¨ Direction £¬±£Ö¤µçÁ÷µÄ·½ÏòÊÇÁ÷³ö½ØÃæ¡£

Ñ¡ÖÐÖмäµÄÏßȦ½ØÃæ

Maxwell > Excitations > Assign > Current Base Name: PhaseB_in Value: Mag Type: Stranded

Ñ¡ÖÐÖмäÏßȦµÄÁíÒ»½ØÃ棺

Maxwell > Excitations > Assign > Current Base Name: PhaseB_out Value: Mag Type: Stranded

µã»÷ Swap Direction£¬±£Ö¤µçÁ÷µÄ·½ÏòÊÇÁ÷³ö½ØÃæ¡£

Ñ¡ÖÐ×î×ó±ßµÄÏßȦ½ØÃæ

Maxwell > Excitations > Assign > Current Base Name: PhaseC_in Value: -0.5*Mag Type: Stranded

Ñ¡ÖÐ×î×ó±ßÏßȦµÄÁíÒ»½ØÃ棺

Maxwell > Excitations > Assign > Current

ÁªÏµ¿Í·þ£º779662525#qq.com(#Ìæ»»Îª@)