立面图

四、面板验算

面板类型 面板抗弯强度设计值[f](N/mm) 2覆面木胶合板 15 面板厚度(mm) 面板弹性模量E(N/mm) 215 10000 取单位宽度1000mm,按二等跨连续梁计算,计算简图如下:

W=bh2/6=1000×15×15/6=37500mm3,I=bh3/12=1000×15×15×15/12=

28

281250mm4

q1=0.9max[1.2(G1k+ (G2k+G3k)×h)+1.4Q2k,1.35(G1k+

(G2k+G3k)×h)+1.4×0.7Q2k]×b=0.9max[1.2×(0.1+(24+1.5)×0.75)+1.4×2,1.35×(0.1+(24+1.5)×0.75)+1.4×0.7×2]×1=25.12kN/m

q1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×0.75]×1=23.36kN/m

q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.76kN/m q2=(G1k+ (G2k+G3k)×h)×b=[0.1+(24+1.5)×0.75]×1=19.22kN/m 1、强度验算

Mmax=0.125q1L2=0.125q1l2=0.125×25.12×0.152=0.07kN·m σ=Mmax/W=0.07×106/37500=1.88N/mm2≤[f]=15N/mm2 满足要求! 2、挠度验算

νmax=0.521qL4/(100EI)=0.521×19.22×1504/(100×10000×281250)=0.018mm≤[ν]=l/400=150/400=0.38mm 满足要求! 3、支座反力计算

设计值(承载能力极限状态)

R1=R3=0.375 q1静l +0.437 q1活l=0.375×23.36×0.15+0.437×1.76×0.15=1.43kN R2=1.25q1l=1.25×25.12×0.15=4.71kN 标准值(正常使用极限状态)

R1'=R3'=0.375 q2l=0.375×19.22×0.15=1.08kN R2'=1.25q2l=1.25×19.22×0.15=3.6kN

五、小梁验算

小梁类型 小梁抗弯强度设计值[f](N/mm) 小梁弹性模量E(N/mm) 小梁截面惯性矩I(cm) 422方木 15.44 9350 256 小梁材料规格(mm) 小梁抗剪强度设计值[τ](N/mm) 小梁截面抵抗矩W(cm) 3260×80 1.78 64 29

为简化计算,按四等跨连续梁和悬臂梁分别计算,如下图:

q1=

max{1.43+0.9×1.35×[(0.3-0.1)×0.3/2+0.5×(0.75-0.14)]+0.9max[1.2×(0.5+(24+1.1)×0.14)+1.4×2,1.35×(0.5+(24+1.1)×0.14)+1.4×0.7×2]×max[0.4-0.3/2,(0.79-0.4)-0.3/2]/2×1,4.71+0.9×1.35×(0.3-0.1)×0.3/2}=4.75kN/m q2=

max[1.08+(0.3-0.1)×0.3/2+0.5×(0.75-0.14)+(0.5+(24+1.1)×0.14)×max[0.4-0.3/2,(0.79-0.4)-0.3/2]/2×1,3.6+(0.3-0.1)×0.3/2]=3.63kN/m 1、抗弯验算

Mmax=max[0.107q1l12,0.5q1l22]=max[0.107×4.75×0.52,0.5×4.75×0.12]=0.13kN·m

σ=Mmax/W=0.13×106/64000=1.98N/mm2≤[f]=15.44N/mm2 满足要求! 2、抗剪验算

Vmax=max[0.607q1l1,q1l2]=max[0.607×4.75×0.5,4.75×0.1]=1.441kN

30

τmax=3Vmax/(2bh0)=3×1.441×1000/(2×60×80)=0.45N/mm2≤[τ]=1.78N/mm2 满足要求! 3、挠度验算

ν1=0.632q2l14/(100EI)=0.632×3.63×5004/(100×9350×2560000)=0.06mm≤[ν]=l/400=500/400=1.25mm

ν2=q2l24/(8EI)=3.63×1004/(8×9350×2560000)=0mm≤[ν]=l/400=100/400=0.25mm 满足要求! 4、支座反力计算

梁头处(即梁底支撑小梁悬挑段根部) 承载能力极限状态

Rmax=max[1.143q1l1,0.393q1l1+q1l2]=max[1.143×4.75×0.5,0.393×4.75×0.5+4.75×0.1]=2.71kN

同理可得,梁底支撑小梁所受最大支座反力依次为R1=R3=1.53kN,R2=2.71kN

正常使用极限状态

R'max=max[1.143q2l1,0.393q2l1+q2l2]=max[1.143×3.63×0.5,0.393×3.63×0.5+3.63×0.1]=2.08kN

同理可得,梁底支撑小梁所受最大支座反力依次为R'1=R'3=1.33kN,R'2=2.08kN

六、主梁验算

主梁类型 主梁弹性模量E(N/mm) 主梁抗剪强度设计值[τ](N/mm) 主梁截面抵抗矩W(cm) 322钢管 206000 125 4.49 主梁材料规格(mm) 主梁抗弯强度设计值[f](N/mm) 主梁截面惯性矩I(cm) 42Ф48×3 205 10.78 主梁自重忽略不计,计算简图如下:

31