ABAQUS³£¼ûÎÊÌâ»ã×Ü - 1.0°æ ÏÂÔر¾ÎÄ

ÔÚ¾²Á¦·ÖÎöÖУ¬±ØÐë¶ÔÄ£ÐÍÖÐËùÓÐʵÌåµÄËùÓÐƽÒƺÍת¶¯×ÔÓɶÈÉ϶¨Òå×ã¹»µÄÔ¼ÊøÌõ¼þ£¬ÒÔ±ÜÃâËüÃdzöÏÖ²»È·¶¨µÄ¸ÕÌåλÒÆ¡£·ñÔò¾Í»á¿´µ½msgÎļþÖгöÏÖ

WARNING: SOLVER PROBLEM. NUMERICAL SINGULARITY

Õâʱ·ÖÎöÒ»°ãÎÞ·¨ÊÕÁ²¡£

ÏÂÃæÊÇÂÛ̳ÉÏ»ØÌûµÄʵÀý£º

http://www.simwe.com/forum/viewthread.php?tid=419588

ÎÊ£ºÓо¯¸æ˵һ¸öµã×ÔÓɶÈ1£¬×ÔÓɶÈ2Öµ¶¼ºÜ´ó£¬µ«ÊǼì²é·¢ÏÖÕâ¸öµãûÎÊÌ⣬±ß½çÌõ¼þʲôµÄҲûÎÊÌ⣬ÕâÔõô»ØÊÂÄØ£¿

***WARNING: SOLVER PROBLEM. NUMERICAL SINGULARITY WHEN PROCESSING NODE 15294 D.O.F. 2 RATIO = 2.48305E+11

´ð£º\˵Ã÷NODE 15294 ËùÔÚµÄʵÌåÔÚ·½Ïò2³öÏÖÎÞÏÞ´óµÄ¸ÕÌåλÒÆ¡£

¿ÉÒÔÔÚ´ËʵÌåÉϵÄÈÎÒâÒ»µãºÍµØÃæÖ®¼ä¶¨ÒåÒ»¸öºÜÈíµÄµ¯»É£¬ÒÔÏû³ý¸ÕÌåλÒÆ¡£·½·¨ÊÇ£ºinteractionÄ£¿é£¬²Ëµ¥special / springs-dashpots / create, Ñ¡connect points to ground, Ñ¡½Úµã£¬Degree of freedom ÉèΪ³öÏÖÁ˸ÕÌåλÒƵÄ×ÔÓɶȣ¬spring stiffnessΪһ¸ö½ÏСµÄÖµ£¨Ì«Ð¡Ôò²»×ãÒÔÏû³ý¸ÕÌåλÒÆ£¬Ì«´óÔò»áÓ°Ïì±äÐΣ©¡£

Èç¹û¶à¸ö·½ÏòÉϳöÏÖÁ˸ÕÌåλÒÆ£¬¾ÍÒª·Ö±ðÔÚÏàÓ¦µÄ·½ÏòÉϸ÷¶¨ÒåÒ»¸öµ¯»É¡£

spring ËùÔڵĽڵãÔÚµ¯»É·½ÏòµÄλÒƳËÒÔspring stiffness£¬¾ÍÊǵ¯»ÉËù·Öµ£µÄÔغɣ¬ËüÓ¦¸ÃԶԶСÓÚÔÚ´Ë·½ÏòÉϵÄÍâÔغɡ£Èç¹ûÄ£ÐÍλÒƺÜС£¬ÎÒ³£³£°Ñspring stiffnessÉèΪ1.

http://www.simwe.com/forum/viewthread.php?tid=686203

ÎÊ£ºÎÒ×öÁËÒ»ÍÖÔ²Îï½Ó´¥Æ½ÃæµÄÄ£ÐÍ£¬½Ó´¥ÊÜÁ¦ºó£¬ÍÖÔ²ÎԼÊøΪ¹Ì¶¨£©Æ½ÒÆÁË£¬²»ÖªÊÇɶԭÒò

´ð£ºÍÖԲûƽÒÆ°¡£¬Ö»¿´µ½Æ½°åƽÒÆÁË¡£Æ½°åÔÚu1ÉÏûÓб߽çÌõ¼þ£¬½Ó´¥ÃæÓÖ²»ÊÇˮƽµÄ£¬µ±È»ÊÜÁ¦ºó»áƽÒƵġ£

ÁíÍ⣬ÍÖÔ²¶¥²¿Íø¸ñÐÎ×´Ì«²î£¬½Ó´¥ÇøÓòµÄÍø¸ñҪϸ»¯¡£

ÕâÊÇ»ù±¾¸ÅÄî°¡£¬¾²Ì¬·ÖÎöÖУ¬Ã¿¸öʵÌåµÄÿ¸ö×ÔÓɶÈÉ϶¼ÒªÓÐ×ã¹»µÄÔ¼Êø£¬·ñÔòËü»áÓв»È·¶¨µÄ¸ÕÌåλÒÆ»òÐýת.

ÿ´Î¼ÆËãʱ£¬¶¼Ó¦¸Ã¿´msgÎļþÖÐÓÐûÓÐwarning»òerror¡£ÄãµÄmsgÎļþÖÐÓÐ

warning: SOLVER PROBLEM. NUMERICAL SINGULARITY WHEN PROCESSING NODE FLAT-1.14 D.O.F. 1 RATIO = 2.50278E+010.

˵Ã÷ FLAT-1µÄD.O.F. 1 ÉϳöÏÖÁËÎÞÏÞ´óµÄ¸ÕÌåλÒÆ¡£Ïû³ýµÄ·½Ê½¿ÉÒÔÊDZ߽çÌõ¼þ£¬Ô¼Êø£¬½Ó´¥£¬Ä¦²Á£¬µ¯»ÉµÈ¡£ÄãÈç¹û²»Ï£Íûƽ°åÔÚx·½ÏòÔ˶¯£¬ÐèҪʩ¼Ó±ß½çÌõ¼þu1=0.

¶Ô³ÆÎÊÌ⣬¶Ô1/2½¨Ä££¬Ô¼ÊøÕû¸ö¶Ô³ÆÃæÉϵÄU1. ²»¶Ô³ÆµÄ»°£¬Ò²ÒªÏëÆäËû°ì·¨Ê©¼Ó×ã¹»µÄÔ¼Êø¡£

Èç¹ûÖ»ÓиºÌØÕ÷Öµ¾¯¸æ£¬Ã»ÓÐnumberical singularity, ¼ÆËãÄÜÊÕÁ²£¬¾ÍûÎÊÌâ¡£

http://www.simwe.com/forum/viewthread.php?tid=690585&highlight=?¨´¨°??a???¡êD¨ª¨¤?¦Ì?????2??t1?

´ð£ºÒѾ­ËµµÃû·¨ÔÙÃ÷°×ÁË¡£Äã¼ÓλÒÆÔغɵÄÄ£ÐÍspring_contact.inpÀ

- Flat-1: U1=U2=0

- Flat-2: U1=0, U2Êܵ¯»ÉÔ¼Êø - ÍÖÔ²£º U1=0, U2Óиø¶¨µÄλÒÆ

ËùÒÔÕâ¸öÄ£ÐÍÀïµÄÿ¸ö²¿¼þ¹ØÓÚx,yÖáµÄ¸ÕÌåƽÒƺ͹ØÓÚzÖáµÄ¸ÕÌåת¶¯¶¼µÃµ½ÁË×ã¹»µÄÔ¼Êø¡£

Äã¼ÓÁ¦ÔغɵÄÄ£ÐÍsphere_flat.inpÀ

- ÍÖÔ²£º U1=U2=0, ûÎÊÌâ¡£

- ƽ°å: y·½ÏòÊÜÁ¦£¬ÉÏÃæºÍÍÖÔ²½Ó´¥£¬ËùÒÔy·½ÏòҲûÎÊÌâ¡£µ«x·½ÏòûÓÐÊ©¼ÓÈκÎÔ¼Êø£¬¾¡¹ÜÕâ¸ö·½ÏòûÓÐÁ¦£¬¶ÔÄãÀ´ËµÆ½°å²»»á·¢Éúx·½ÏòµÄ¸ÕÌåƽÒÆ£¬µ«Õâ²»·ûºÏÓÐÏÞÔªµÄ¼ÆËãÒªÇó£¬x·½ÏòµÄ¸ÕÌåλÒÆÊDz»È·¶¨µÄ¡£Õâ²¢²»ÊÇ˵£¬Äã»áÔÚºó´¦ÀíÖп´µ½x·½Ïò·¢ÉúºÜ´óµÄ¸ÕÌåλÒÆ£¬¶øÊÇABAQUS¸ù±¾¾ÍÎÞ·¨¼ÆË㣬µÃ²»µ½Èκνá¹û¡£ÕâºÍy·½ÏòµÄÔغɴóСûÓйØϵ¡£

ËùÒÔÒª¸ù¾Ý¶Ô³ÆÐÔ¶Ô1/2½¨Ä££¬Ô¼ÊøÕû¸ö¶Ô³ÆÃæÉϵÄU1.

²»Óÿ´job diagnostics £¬´íÎóºÍ¾¯¸æÐÅÏ¢¶¼ÔÚ·ÖÎöÉú³ÉµÄÎļþsphere_flat.msgÀï¡£

ÄãÒªÊÇ»¹²»Ã÷°×£¬ÎÒ¾ÍÖ»ÄÜÈ¥ÌøÂ¥ÁË¡£

http://www.simwe.com/forum/viewthread.php?tid=695202

ÎÊ£ºÎÒÓÃconstrain_equation ½«ÁººÍ°åϵÔÚÒ»Æ𣬽øÐоù²¼Á¦ÊÜѹ·ÖÎö£¬µ«ÊÇ·¢ÏÖ£¬µ±ÎÒ½«1£¬3×ÔÓɶÈÏÞÖÆʱ£¬°åÁº¶¼ÍäÇúÁË£¬2·½ÏòÓÐÆ«ÒÆ

µ«ÊÇÎÒ½«1£¬2£¬3×ÔÓɶÈÒ»ÆðÏÞÖÆʱ£¬·¢ÏÖ°åÁº¶¼²»ÍäÁË£¬¿ÉÄÜÔ­ÀíÉÏÓеãÎÊÌ⣬¸½ÉÏÎļþ£¬ÄÄλ´óϺ¸øÓëÖ¸µã£¡£¡Ð»Ð»

ºóÀ´ÓÃtie ÊÔÁËÒ»ÏÂ,Ч¹û»¹Í¦ºÃµÄ,¾ÍÊDz»ÖªµÀ¶Ô²»¶Ô,ÒòΪ°ïÖúÎļþÀï˵tieÓÃÓÚ¶¨ÒåÃæºÍÃæµÄ,ÁººÍÃæÕâÑù¶¨Òå²»ÖªµÀÐв»??

´ð£ºÃ¿´Î¼ÆËãʱ£¬¶¼Ó¦¸Ã¿´msgÎļþÖÐÓÐûÓÐwarning»òerror. Á½¸öÄ£Ð͵ÄÔÚmsgÎļþÖж¼ÓÐ

***WARNING: SOLVER PROBLEM. NUMERICAL SINGULARITY WHEN PROCESSING NODE 104 D.O.F. 4 RATIO = 3.80284E+015.

˵Ã÷ D.O.F. 4 ÉÏȱ·¦Ô¼Êø¡£ÄãÖ»Ô¼ÊøU1,U2,U3, ¶ÔʵÌåµ¥ÔªÊÇ¿ÉÒԵģ¬µ«shellºÍbeamµ¥Ôª¶¼ÓÐÐýת×ÔÓɶȣ¬ÒªÊ©¼Ó×ã¹»µÄÔ¼ÊøÀ´Ïû³ý¸ÕÌåλÒÆ £¨ËäÈ»¶ÔÄãÀ´Ëµ£¬Ô¼ÊøÁËÁ½¶ËµÄU1,U2,U3¾ÍûÓиÕÌåλÒÆÁË£¬µ«Õâ²»·ûºÏABAQUSµÄÒªÇ󣩡£ÄãµÄµÚÒ»¸öÄ£ÐÍËäÈ»Ëã³öÀ´ÁË£¬µ«½á¹û²»Ò»¶¨ÕýÈ·¡£

½â¾ö·½·¨£º¶Ô³ÆÄ£ÐÍ¿ÉÈ¡Ò»°ë£¬ÔÚ¶Ô³ÆÃæÉÏÔ¼ÊøUR1,UR2,UR3.

ÁººÍÃætieÓ¦¸Ã¿ÉÒÔ¡£

4£®¹ýÔ¼Êø£¨Overconstraint£©

http://www.simwe.com/forum/viewthread.php?tid=718246

ÎÊ£º×öÁ˸ö»ù¿Ó¿ªÍÚµÄÌ⣬³öÏÖÁ˺ܶà¹ýÔ¼ÊøÎÊÌ⣬Ôõô½â¾ö¹ýÔ¼ÊøµÄÎÊÌâѽ£¿

´ð£º²Î¼û

http://www.simwe.com/forum/post/view?bid=31&id=705685&tpg=1&ppg=1&sty=1#705754

½Ó´¥¶ÔµÄÖ÷ÃæÉϲ»ÄÜÓмâ½Ç£¬×®µÄÁ½¸ö²àÃæÒª·Ö±ð¶¨Òå½Ó´¥¶Ô£¬µ×²¿¿ÉÄÜ¿ÉÒÔÓÃtie.

slave surfaceµÄÍø¸ñÒª±Èmaster surfaceϸ¡£

¹ýÔ¼Êø¿ÉÄÜÊÇÒòΪ±»ÍÚµÄÍÁÉϼȶ¨ÒåÁ˽Ӵ¥£¬ÓÖÒª±»É±ËÀ£¬Õâ¶þÕßÏàì¶Ü¡£¿ÉÒÔÊÔÊÔΪÿ¶Î±»ÍÚµÄÍÁµ¥¶À¶¨ÒåÒ»¸ö½Ó´¥£¬ÍÚÍÁʱÏÈdeactivateÕâ¸ö½Ó´¥£¬ÔÙɱËÀµ¥Ôª¡£

http://www.simwe.com/forum/viewthread.php?tid=724602&pid=738324&page=1&extra=page=1#pid738324

ÎÊ£º

ÔÚjob-monitorÖÐÓиö¾¯¸æÊÇÕâÑù

Solver problem. Zero pivot when processing D.O.F. 2 of 1 nodes. The nodes have been identified in node set WarnNodeSolvProbZeroPiv_2_1_1_1_1.

ÊDz»ÊǸնȾØÕóµÄÎÊÌ⣿ÎҵijÌÐòÊÇÕÕ×ÅÒ»¸ö½²×ùµÄ²ÄÁÏÉϳ­ÏÂÀ´µÄ£¬Ó¦¸ÃûʲôÎÊÌâµÄÄÄλÀÏÐÖÄÜÖ¸µãÏ£¡

SimWe·ÂÕæÂÛ̳5o-p:td/k+K¨°[)T

·ÂÕæ·ÖÎöÓÐÏÞԪģÄâ

´ð£º

Zero pivot ÍùÍùÒâζ×Å OVERCONSTRAINT¡£´Ë¾¯¸æÐÅÏ¢Èç¹ûÖ»ÊdzöÏÖÔÚdatÎļþÖУ¬Ã»ÓгöÏÖÔÚmsgÎļþÖУ¬¾ÍûÎÊÌ⣬˵Ã÷ABAQUS×Ô¶¯½â¾öÁ˹ýÔ¼ÊøÎÊÌâ¡£

Èç¹ûoverconstraint¾¯¸æÐÅÏ¢Ò²³öÏÖÔÚmsgÎļþÖУ¬ËµÃ÷ABAQUSÎÞ·¨×Ô¶¯½â¾ö´ËÎÊÌ⣬Õâʱ·ÖÎöÍùÍù²»»áÊÕÁ²£¬ÔÚºó´¦Àíʱ¿ÉÒÔÓÃdisplay groupÏÔʾ³öÏÖ¹ýÔ¼ÊøµÄnode set WarnNodeSolvProbZeroPiv_2_1_1_1_1. ÕâʱÐèÒªÄã×Ô¼ºÐÞ¸ÄÄ£ÐÍ£¬±ÜÃâ¹ýÔ¼Êø¡£

5£®ÆäËû³£¼ûerrorºÍwarningÐÅÏ¢

http://www.simwe.com/forum/viewthread.php?tid=692452

ÎÊ£ºThere is zero MOMENT everywhere in the model based on the default criterion. please check the value of the average MOMENT during the current iteration to verify that the MOMENT is small enough to be treated as zero. if not, please use the solution controls to reset the criterion for zero MOMENT.

¸ÃÔõô°ì°¡£¬Ð»Ð»´ó¼ÒÁË£¡

´ð£ºÕâÖ»ÊÇÌáÐÑÄãÄ£ÐÍÖÐÖ»ÓÐλÒƱ߽çÌõ¼þ£¬Ã»ÓÐÊ©¼ÓÔغɡ£Èç¹ûÄÜÊÕÁ²£¬½á¹ûÒ²Õý³££¬¾Íû¹Øϵ¡£ºÜ¶à¾¯¸æ¶¼Ö»ÊÇÌáʾÐÅÏ¢£¬²»Òâζ×ÅÄ£ÐÍÓдíÎó¡£

http://www.simwe.com/forum/viewthread.php?tid=683255

ÎÊ£º1 ***WARNING: DEGREE OF FREEDOM 4 IS NOT ACTIVE IN THIS MODEL AND CAN NOT BE RESTRAINED

2 ***ERROR: TOO MANY ATTEMPTS MADE FOR THIS INCREMENT: ANALYSIS TERMINATED

3 ***ERROR: NODE SET ASSEMBLY_CENTER HAS NOT BEEN DEFINED

4 ***ERROR: A BOUNDARY CONDITION HAS BEEN SPECIFIED ON NODE SET ASSEMBLY_CENTER BUT THIS NODE SET IS NOT ACTIVE IN THE MODEL

¶ÔÓÚÒÔÉÏ´íÎó£¬ÄÄλ´óÏÀÖ¸µãһϣ¬ÊÇÄÄÀï³öÏÖÁË´íÎó£¬ÈçºÎ½â¾öËü£¬ Ôڴ˱íʾ¸Ðл¡£

´ð£º

1£®¨DDEGREE OF FREEDOM 4 IS NOT ACTIVE¡¬£ººÜ¶à¾¯¸æÐÅÏ¢¶¼²»Òâζ×ÅÓдíÎ󣬿ÉÒÔ²»¹ÜËü¡£

2£®¨DTOO MANY ATTEMPTS¡¬£ºÈç¹ûÒÔµ±Ç°µÄʱ¼äÔöÁ¿²½ÎÞ·¨Ôڹ涨µÄµü´ú´ÎÊýÄÚ´ïµ½ÊÕÁ²£¬ABAQUS»á×Ô¶¯¼õСʱ¼äÔöÁ¿²½£¬ÖØпªÊ¼µü´ú£¬¼´ËùνµÄ¨DCutback¡¬¡£Èç¹ûÕâÑùÈÔ²»ÄÜÊÕÁ²£¬Ôò»á¼ÌÐø¼õСʱ¼äÔöÁ¿²½¡£Èç¹û´ïµ½Á˹涨µÄCutback×î´ó´ÎÊý£¨Ä¬ÈÏֵΪ5´Î£©£¬»òʱ¼äÔöÁ¿²½³¤¼õСµ½Ëù¹æ¶¨µÄ×îСÏ޶ȣ¨Ä¬ÈÏֵΪ10-5£©£¬ABAQUS¾Í»áÖÐÖ¹·ÖÎö£¬²¢ÔÚMSGÎļþµÄ½áβ´¦ÏÔʾÉÏÊö´íÎóÐÅÏ¢¡£

²»ÊÕÁ²µÄ¿ÉÄÜÔ­ÒòºÜ¶à£¬¾ÍÏñÌìÉϵÄÐÇÐÇ£¬ÊýÒ²Êý²»Çå¡£Ëùν ¨DÕýÈ·µÄÄ£ÐͶ¼ÊÇÏàËƵģ¬²»ÕýÈ·µÄÄ£ÐÍÔò¸÷Óи÷µÄ²»ÕýÈ·¡¬¡£

3£®¨DNODE SET ASSEMBLY_CENTER HAS NOT BEEN DEFINED¡¬£ºÄ£ÐÍÖÐÓõ½ÁËÃûΪcenterµÄ¼¯ºÏ£¬µ«Ã»Óж¨ÒåËü¡£

4£®¨D***ERROR: A BOUNDARY CONDITION HAS BEEN SPECIFIED ON NODE SET

ASSEMBLY_CENTER¡£BUT THIS NODE SET IS NOT ACTIVE IN THE MODEL¡¬£ºÍ¬ÉÏ¡£

ÔËÐÐINPÎļþʱ»áµ÷ÓÃ×Ó³ÌÐò£¬¶þÕß²»Äܼ¯³ÉÔÚÒ»Æð¡£

http://www.simwe.com/forum/viewthread.php?tid=690862

ÎÊ£º´ó¼ÒºÃ£¬ÎÒÊÇÒ»¸öAQBAQUSµÄ³õѧÕߣ¬×î½üÔÚ¼ÆËãÈíÍÁ¹Ì½áÎÊÌâʱ,×ÜÊdzöÏÖ FIXED TIME INCREMENT IS TOO LARGE

ÕâÑùµÄÎÊÌ⣬ÂÅÊÔÂÅ°Ü£¬ËùÒԷdz£ÏëÖªµÀÈçºÎ²ÅÄÜÕýÈ·ÉèÖÃtime incrementÑ¡Ïî¼°ÆäÖеÄÇÏÃÅ£¬²»ÖªµÀÄÄλ¸ßÊÖ¿ÏÖ¸µ¼Ò»¶þ£¬±¾È˲»Ê¤¸Ð¼¤¡£

´ð£ºÑÒÍÁÎÒû¸ã¹ý£¬²»Ò»¶¨ÊÇincrementµÄÎÊÌ⣬Äã¼ì²éһϵ¥ÔªÀàÐÍ£¬²ÄÁϲÎÊý£¬µ¥Î»£¬³õʼµØÓ¦Á¦µÈÊÇ·ñÕýÈ·¡£½¨ÒéÔÚ°ïÖúÎļþ»òÂÛ̳ÀïÕÒÒ»¸öÕýÈ·µÄÀý×Ó£¬°ÑËüÒ»µãµã¸Ä³ÉÄãµÄ²ÎÊý£¬¸Äµ½ÄÄÀï³ö´íÁË£¬¾ÍÕÒµ½ÁËÎÊÌâËùÔÚ¡£

http://www.simwe.com/forum/viewthread.php?tid=697404

ÎÊ£ºÎÒÔÚÔËÐÐabaqusʱ³öÏÖ´íÎó:

abaqus error:the executable C:\\abaqus\\6.5-1\\exec\\standard.exe aborted with system error \¾Ü¾ø·ÃÎÊ\

´ð£ºÏÈ¿´datºÍmsgÎļþÖÐÓÐûÓÐwarning»òerror£¬Èç¹ûûÓУ¬³£¼ûµÄÓÐÈýÖÖÔ­Òò£º

- abaqus_v6.envÖеIJÎÊýpre_memoryÉèÖõùý´ó

- Óû§×Ó³ÌÐòÖгöÏÖÎÊÌâ¡£¼ì²éÔÚINPÎļþÖе÷ÓÃÓû§×Ó³ÌÐòʱ£¬ÊÇ·ñʹÓÃÁËÕýÈ·µÄ²ÎÊý¡£¿ÉÒÔ³¢ÊÔÓÃÒ»¸ö¼òµ¥µÄÀý×ÓÀ´µ÷ÊÔÓû§×Ó³ÌÐò£¬È·±£ÆäÕýÈ·ÐÔ¡£ÁíÍâÔÚ±àдÓû§×Ó³ÌÐòʱ£¬Ó¦×¢Ò⾡¿ÉÄܶàÉèÖÃһЩ³ö´íÌáʾ¡£