ZHEJIANG REXENSETECHNOLOGY
FCCID: O46RY12M01
CO.,LTD. Page21of49
Duty Cycle
Theworst-casedutycyclefor typicalEUToperationisshown below.
Thepulsetrainof theEUTextendsbeyond100 msas shown inthefollowingplot:
100ms period
Thisperiodcontainstwo kindsof typicalpulse,thelongoneandtheshort one.
AudixTechnology(Shanghai)Co.,Ltd.ReportNo.:ACI-F12088
ZHEJIANG REXENSETECHNOLOGY
FCCID: O46RY12M01
CO.,LTD. Page22of49
Typical pulse 1 width (4.13 ms)
Typical pulse 2 width (0.8921 ms)
Duty cycle=2(4.13ms)+1(0.8921ms)=9.1521 msina100msperiod Duty cyclefactor=|20log(9.1521 /100)| =20.77 dB
We use 20 dB as the duty cycle factorin the average value calculation.
AudixTechnology(Shanghai)Co.,Ltd.ReportNo.:ACI-F12088
ZHEJIANG REXENSETECHNOLOGY
FCCID: O46RY12M01
CO.,LTD. Page23of49
AVResult on CH 11
MaximumAVvalue@2375.77MHz =-45.6 dBm Limit=-41.2 dBm ResultisPASS
AudixTechnology(Shanghai)Co.,Ltd.ReportNo.:ACI-F12088
ZHEJIANG REXENSETECHNOLOGY
FCCID: O46RY12M01
CO.,LTD. Page24of49
PK Result on CH 11
PK Result=-39.25 dBm Limit=-21.2 dBm ResultisPASS
AudixTechnology(Shanghai)Co.,Ltd.ReportNo.:ACI-F12088