relap5中文版本 下载本文

Relap5输入数据卡要求

Relap5输入数据卡要求························································································································7 A-1 引言··············································································································································7 A-1.1 控制格式····································································································································7 A-1.2 数据卡的编制····························································································································7 A-1.3 题目卡········································································································································7 A-1.4 注释卡········································································································································7 A-1.5 数据卡········································································································································8 A-1.6 继续卡········································································································································8 A-1.7 终止卡········································································································································9 A-1.8 序列展开格式····························································································································9 A-1.9 上/下敏感性·······························································································································9 A-1.10 数据卡的要求··························································································································9 A-1.11 输入错误扑捉··························································································································9 A-2 各类控制卡片·····························································································································11 A-2.1 100卡片,问题类型和选择···································································································11 A-2.2 101卡,输入检查或运行选择································································································11 A-2.3 102卡,单位选择···················································································································11 A-2.4 103卡,再启动——输入文件控制卡····················································································12 A-2.5 104卡片,再启动——绘图文件控制卡················································································12 A-2.6 105卡,CPU时间保留卡·······································································································12 A-2.7 110卡,非凝结气体种类········································································································13 A-2.8 115卡,非凝结气体和金属种类质量份额············································································13 A-2.8.1 Card 115,非凝结气初始质量份额····················································································13 A-2.8.2 Card 116,材料初始质量份额····························································································13 A-2.9 118卡,传热控制卡···············································································································13 A-2.10 120-129卡,水力学系统控制卡··························································································13 A-2.11 140-147卡,自我初始化选择控制卡···················································································14 A-2.11.1 140卡,自我初始化控制卡·······························································································14 A-2.11.2 141-142卡,自我初始化泵控制器和标识卡····································································14 A-2.11.3 143-144卡,自我初始化蒸汽流动控制器标识卡····························································14 A-2.11.4 145-146卡,自我初始化给水控制器标识卡····································································15 A-2.11.5 147卡,压力和容积控制部件标识卡···············································································15 A-3 200-299卡 时间步长控制卡·····································································································16 A-3.1 200卡,初始时间值···············································································································16 A-3.2 201-299卡,时间步长控制····································································································16 A-4 301-399卡片,小编辑要求·······································································································17 A-4.1 常用量······································································································································17 A-4.2 与部件有关的量······················································································································17 A-4.3 与控制体有关的量··················································································································18 A-4.4 与接管有关的量······················································································································20 A-4.5 与热构件有关的量··················································································································21 A-4.6 反应堆动力学量······················································································································21

A-4.7 控制系统量······························································································································21 A-4.8 扩大编辑绘图变量··················································································································21 A-4.8.1 一般量···································································································································22 A-4.8.2 与部件相关的量···················································································································22 A-4.8.3 与控制体相关的量···············································································································22 A-4.8.4 与接管相关的量···················································································································23 A-4.8.5 与热构件相关的量···············································································································24 A-4.8.6 与再淹没相关的量···············································································································24 A-5 400-799卡片或20600000-206200000卡片 TRIP输入数据··················································25 A-5.1 400卡,TRIP取消卡··············································································································25 A-5.3 401-599卡或20600010-20610000卡,变量TRIP卡····························································25 A-5.4 601-799卡或20620010-20620006卡逻辑TRIP卡································································26 A-5.5 600卡,终止前进TRIP卡······································································································26 A-6 801-999卡 交互式输入数据·································································································27 A-7 CCCXXNN卡,水动力学部件·································································································28 A-7.1 CCC0000卡,部件名和类型·································································································28 A-7.2 单一控制体部件······················································································································28 A-7.2.1 CCC0101至CCC0109卡,单一控制体几何卡·································································28 A-7.2.2 CCC0200卡,单一控制体初始条件··················································································29 A-7.3 时间相关控制体部件··············································································································30 A-7.3.1 CCC0101N至CCC0109卡,时间相关控制体几何卡·······················································30 A-7.3.2 CCC0200卡,时间相关控制体数据控制字码···································································30 A-7.3.3 CCC0201至CCC0299卡,时间相关控制体数据卡·························································31 A-7.4 单一接管部件··························································································································32 A-7.4.1 CCC0101至CCC0109卡,单一接管几何卡·····································································32 A-7.4.2 CCC110卡,单一接管直径及CCFL数据卡······································································33 A-7.4.3 CCC0201 卡单一接管的初始条件·····················································································33 A7.5 时间相关接管部件···················································································································33 A-7.5.1 CCC0101 卡,时间相关接管几何卡··················································································33 A-7.5.2 CCC0200卡,时间相半接管控字码··················································································34 A-7.5.3 CCC0201至CCC0299卡,时间相关接管数据卡·····························································34 A-7.6 管型或环型部件······················································································································34 A-7.6.1 CCC0001卡,管型或环型部件信息卡··············································································34 A-7.6.2 CCC0101至CCC01999卡,管型或环型控制体面积·······················································35 A-7.6.3 CCC0201至CCC02999卡,管型或环型接管流通面积···················································35 A-7.6.4 CCC0301至CCC03999卡,管型或环型控制体的长度···················································35 A-7.6.5 CCC0401 至CCC0499卡,管型或环形控制体的容积···············································35 A-7.6.6 CCC0501至CCC0599卡,管型或环形控制体(水平)角··············································35 A-7.6.7 CCC0601至CCC0699卡,管型或环形控制体垂直角·····················································35 A-7.6.8 CCC0701至CCC0799卡,管型或环形控制体高度变化·················································35 A-7.6.9 CCC0801至CCC0899卡,管型或环形控制体摩擦系数·················································36 A-7.6.10 CCC0901至CCC0999卡,管型或环形控制体损失系数················································36 A-7.6.11 CCC1001至CCC1099卡,管型或环形控制体控制标识················································36 A-7.6.12 CCC1101至CCC1199卡,管型或环形接管控制标识····················································36

A-7.6.13 CCC1201至CCC1299卡,管型或环形控制体初始条件················································37 A-7.6.14 CCC2001至CCC2099卡,管型或环形初始浓度···························································38 A-7.6.15 CCC1300卡,管型或环形接管工况控制字码·································································38 A-7.6.16 CCC1301至CCC1399卡,管型或环形接管初始条件···················································38 A-7.6.17 CCC1401至CCC1499卡,管型或环形接管直径和CCFL数据卡·································38 A-7.7 分支、分离器,喷射混和器、透平或ECC混和器部件·······················································39 A-7.7.1 分支部件、分离器,喷射混和器、透平或ECC混和器信息卡·········································40 A-7.7.2 CCC0101至CCC0109卡,分支分离器,喷射混合器,透平或ECC混合控制几何卡。······························································································································································40 A-7.7.3 CCC0200卡,分支,分离器,喷射混合器,透平或ECC混合器控制体初始工况。····41 A-7.7.4 CCC0201卡,分支,分离器,喷射混合器,透平或ECC混合器接管几何卡。············42 A-7.7.5 CCCN110卡,分支、分离器、混合器,透平或ECC混合器与接管直径,和CCFL数据卡··························································································································································43 A-7.7.6 CCCN201卡 分支、分离器、喷射混合器、透平或ECC混合器接管的初始条件。·····43 A-7.7.7 CCC0300卡,透平/轴几何卡·····························································································43 A-7.7.8 CCC0400卡,透平性能数据卡··························································································44 A-7.8 阀接管部件······························································································································44 A-7.8.1 CCC0101至CCC0109卡,阀接管几何卡·········································································44 A-7.8.2 CCC0110卡,阀接管直径和CCFL数据卡········································································45 A-7.8.3 CCC0201卡,阀接管初始条件··························································································45 A-7.8.4 CCC0300卡,阀类型卡,这个卡是指定阀类型所要求的。···········································45 A-7.8.5 CCC0301至CCC0399卡,阀数据和初始条件·································································45 A-7.8.5.1 止回阀。····························································································································46 A-7.8.5.2 触发阀。····························································································································46 A-7.8.5.3 惯性阀。····························································································································46 A-7.8.5.4 马达阀。····························································································································46 A-7.8.5.5 伺服阀。····························································································································47 A-7.8.5.6 释放阀。····························································································································47 A-7.8.6 CCC0400至CCC0499卡,阀CSUBV···············································································48 A-7.8.6.1 CCC0401至CCC0499卡,表输入量,这表以三个字码一组输入。W1时通流面积或阀杆位置,必须时归一化的。···············································································································48 A-7.9 泵部件······································································································································48 A-7.9.1 CCC0101至CCC0107卡,泵控制体几何卡·····································································49 A-7.9.2 CCC0108卡,泵入口(吸入)接管卡··············································································49 A-7.9.3 CCC0109卡,泵出口(排出)接管卡··············································································50 A-7.9.4 CCC0110卡,泵入口(吸入)接管直径和CCFL数据卡。·············································50 A-7.9.5 CCC0111卡,泵出口(排出)接管直径和CCFL数据卡·················································50 A-7.9.6 CCC0200卡,泵控制体初始条件······················································································50 A-7.9.7 CCC0201卡,泵入口(吸入)接管初始条件。·······························································51 A-7.9.8 CCC0202卡,泵出口(排出)接管初始条件。·······························································51 A-7.9.9 CCC0301卡,泵标志(index)和选择卡·········································································51 A-7.9.10 CCC0302至CCC0304卡,泵说明卡···············································································52 A-7.9.11 CCC0308卡,泵变量惯性卡····························································································52 A-7.9.12 CCC0309卡,泵轴联接卡································································································53

A-7.9.13 CCC0310,泵停止数据卡·································································································53 A-7.9.14 CCCXX00至CCCXX99卡,单相类比曲线····································································53 A-7.9.15 CCCXX00至CCCXX99卡,两相乘子表·······································································53 A-7.9.16 CCCXX00至CCCXX99卡,两相差额表·······································································53 A-7.9.17 CCC3001至CCC6099卡,表的相对电动力矩数据·······················································54 A-7.9.18 CCC6100卡,泵时间相关速度控制卡············································································54 A-7.9.19 CCC6101至CCC6199卡,泵的时间相关速度卡···························································54 A-7.10 多接管部件····························································································································54 A-7.10.1 CCC0001卡,多接点信息卡····························································································54 A-7.10.2 CCC0NNM卡,多接点几何卡··························································································54 A-7.10.3 CCC1NNM卡,多接管的初始条件卡··············································································56 A-7.10.4 CCC2NNM卡 多接管直径和CCFL数据卡·····································································56 A-7.11 安注箱部件····························································································································56 A-7.11.1 CCC0101至CCC0199卡,安注箱控制体几何卡···························································56 A-7.11.2 CCC0200卡 安注箱水箱热力学初始条件·······································································57 A-7.11.3 CCC1101卡 安注箱接管几何卡·······················································································57 A-7.11.4 CCC2200卡 安注箱初始状况,紧管/波动管线/长度和水箱传热项。························58 A-8 1CCCGXNN 热构件的输入···································································································59 A-8.1 卡1CCCG000, 一般热构件数据卡······················································································59 A-8.1.1 一般热构件数据卡···············································································································59 A-8.1.2 热构件消除卡·······················································································································59 A-8.2 1CCCG001,间隙传导率模型初始间隙压力数据································································60 A-8.3 1CCCG003卡,金属—水反应控制卡··················································································60 A-8.4 1CCCG003卡,燃料包壳变形模型控制卡··········································································60 A-8.5 1CCCG011-1CCCG099卡,间隙变形数据·······································································60 A-8.6 1CCCG100卡,热构件网络标识··························································································60 A-8.7 1CCCG101-1CCCG199卡,热构件网络间隔数据径向信息···········································61 A-8.8 1CCCG201-1CCCG299卡,热构件组成成份数据径向信息···········································61 A-8.9 1CCCG300卡,裂变产物衰变热标识··················································································61 A-8.10 1CCCG301-1CCCG399卡,热构件热源分布数据径向信息·········································61 A-8.11 1CCCG400卡,初始温度标识····························································································61 A-8.12 1CCCG401-1CCCG499卡,初始温度数据·····································································62 A-8.13 1CCCG501-1CCCG599卡,左边界条件卡·····································································62 A-8.14 1CCCG601-1CCCG699卡,右边界条件卡·····································································63 A-8.15 1CCCG701-1CCCG799卡,热源数据卡·········································································63 A-8.16 1CCCG801-1CCCG899卡,附加左边界卡·····································································63 A-8.17 1CCCG901-1CCCG999卡,附加右边界卡·······································································64 A-9 60000000卡 辐射模型控制卡·······························································································64 A-9.1 6SS00000卡,辐射设置卡·····································································································64 A-9.2 6SSNN001-6SSNN099卡,辐射热构件数据········································································64 A-9.3 6SSNN101-6SSNN199卡,辐射范围因子············································································64 A-10 201MMMNN卡 热构件热物性数据·················································································65 A-10.1 201MMM00卡,构件成分类型和数据格式·······································································65 A-10.2 201MMM01-201MMM49卡 热导热率数据或间隙克分子份额数据···························65

A-10.2.1 表格式·································································································································65 A-10.2.2 函数格式·····························································································································65 A-10.3 201MMM51-201MMM99卡,体积热容数据····································································66 A-10.3.1 表格式·································································································································66 A-10.3.2 函数格式·····························································································································66 A-11 卡202TTTNN 通用表格数据·······························································································67 A-11.1 202TTT00卡,表格类型和乘子数据··················································································67 A-11.2 202TTT01-202TTT99卡,总表数据···················································································67 A-12 30000000-30099999卡 点堆动力学····················································································68 A-12.1 30000000卡,反应堆动力学类型卡····················································································68 A-12.2 30000001卡,反应堆动力学信息卡·················································································68 A-12.3 30000002卡,裂变产物裂变信息···················································································68 A-12.4 30000101-30000199卡,缓发中子常数···············································································69 A-12.5 30000201-30000299卡,裂变产物衰变常数·······································································69 A-12.6 30000301-30000399卡,锕系元素衰变常数·······································································69 A-12.7 30000401-30000499卡,堆先前功率史数据·······································································69 A-12.8 30000011-30000020卡,反应性曲线或控制变量号···························································69 A-12.9 30000501-30000599卡,密度反应性表···············································································69 A-12.10 30000601-30000699卡,多普勒反应性表·········································································70 A-12.11 30000701-30000799卡,控制体权重因子·········································································70 A-12.12 30000801-30000899卡,热构件权重因子·········································································70 A-12.13 30001701-30001799卡控制体权重因子·············································································70 A12.14 30001801-30001899,卡热构件权重因子···········································································70 A-12.15 300019C1-300019C9 卡,反馈表坐标数据·······································································71 A-12.16 30002001-30002999卡,反馈表数据·················································································71 A-13 2030000-20499999卡 绘图输入数据····················································································72 A-13.1 203000KK卡,总图题和说明······························································································72 A-13.2 2030000-20300009卡,总图题····························································································72 A-13.3 20300010-20300019卡,通用绘图选择关键字···································································72 A-13.4 20300020卡,通用绘图尺寸································································································74 A-13.5 卡20300030,输入绘图检查要求卡····················································································74 A-13.6 卡 203NNNKK,绘图请示和说明······················································································74 A-13.6.1 卡 203NNN00至203NNN09,绘图请求·········································································74 A-13.6.2 卡203NNN10至203NNN19,自变量请求······································································75 A-13.6.3 卡 203NNN20至203NNN29,绘图比较数据表参照·····················································75 A-13.6.4 卡203NNN30至203NNN32,绘图标题和轴标题。······················································75 A-13.6.5 卡203NNN40至203NNN41,图轴说明··········································································75 A-13.6.5.1 卡203NNN40,自变量轴说明·······················································································76 A-13.6.5.2 卡203NNN41 图变量轴说明·····················································································76 A-13.6.6 卡203NNN50至203NNN59,曲线绘制说明··································································77 A-13.6.7 卡203NNN60至203NNN69,绘图选择变更··································································77 A-13.6.8 卡203NNN70,绘图尺寸变更··························································································77 A-13.7 卡204MMMLL,绘图比较数据表·····················································································77 A-13.7.1 卡204MMM00,绘图比较数据表请求············································································77

A-13.7.2 卡204MMM01至204MMM08 因变量单位转换·························································78 A-13.7.3 卡204MMM10,表自变量·······························································································78 A-13.7.4 卡 204MMM11至204MMM18,自变量单位转换························································79 A-13.7.5 卡 204MMM19,数据曲线说明·······················································································79 A-13.7.6 卡 204MMM20,绘图比较数据表输入数据···································································79 A-14 卡片 205CCCNN-205CCCCN 控制系统输入数据··························································80 A-14.1 20500000卡,控制变量卡类型····························································································80 A-14.2 205CCC00或205CCCC0卡,控制部件类型····································································80 A-14.3 205CCC01到205CCC98或205CCCC1到205CCCC8卡,控制组件数据卡···············81 A-14.3.1 和差部件·····························································································································81 A-14.3.2 乘部件·································································································································81 A-14.3.3 除部件·································································································································81 A-14.3.4 微分部件·····························································································································81 A-14.3.5 积分部件·····························································································································82 A-14.3.6 函数部件·····························································································································82 A-14.3.7 STDFNCTN标准函数部件································································································82 A-14.3.8 延迟部件·····························································································································82 A-14.3.9 单位TRIP部件····················································································································83 A-14.3.10 TRIP延迟部件··················································································································83 A-14.3.11 整数幂部件·······················································································································83 A-14.3.12 实数幂部件·······················································································································83 A-14.3.13 变量幂部件·······················································································································83 A-14.3.14 比例积分部件···················································································································83 A-14.3.15 滞后部件···························································································································84 A-14.3.16 超前滞后部件···················································································································84 A-14.3.17 常数部件···························································································································84 A-14.3.18 传动轴部件·······················································································································85 A-14.3.18.1 卡205CCC01到205CCC05或205CCCC1到205CCCC5传动轴描述卡··············85 A-14.3.18.2 卡205CCC06或205CCCC6发电机描述卡·······························································85 A-14.3.19 PUMPCTL部件···············································································································85 A-14.3.20 STEAMCTL部件·············································································································86 A-14.3.21 FEEDCTL部件················································································································86 A-15 卡1001到1999 STRIP请求数据·························································································87

Relap5输入数据卡要求

A-1 引言

本文完整描述了在用SCDAP/RELAP5程序计算各类问题时数据卡的编写格式和要求。 A-1.1 控制格式

SCDAP/RELAP5输入是用以80字符记录的卡片组来描述的,数据可通过80列穿孔卡片或交互式编辑器或UPDATE实用程序来输入。SCDAP/RELAP5读96字符的记录,如果实际记录少于96列,就在输入的末尾用空格字符加以填充到96列。问题输出的第一部分是多张卡片号顺序递增的96列输入记录。在SCDAP/RELAP5输入中只使用前80列,另外16列是编辑器或UPDATE程序使用时才用的。

大多数交互式编辑器允许输入80列记录。由于许多终端只允许每行输入80列,因而方便的方法是限制数据记录为72列(8列用于填充引号和分隔符),以便使数据记录格式与编辑器格式相同。如果数据格式为72列,引号可能写在72~80列。因为SCDAP/RELAP5使用前80列记录,因而引号就会被SCDAP/RELAP5当作输入处理。为了避免这种情况,可申请编辑器将引号放在81列以后或者不储存引号,这些引号如果保留了,就会在输出的输入数据中反映出来。

如果用UPDATE程序来保留输入卡片组,必须用UPDATE命令规定卡片数据为80列代替缺省值72列。 A-1.2 数据卡的编制

一个SCDAP/RELAP5问题输入卡由两部分组成:RELAP5的热工水力模型和气溶胶模型,以及SCDAP的堆芯特性模型。两部分都按自我格式化输入,但对每一部分输入有轻微的不同规则。输入第一部分至少包括一个题目卡,若干选择性注释卡,数据卡和一个中止卡。这些卡片的清单将被打印在每一个SCDAP/RELAP5问题的开始。除了最后的题目卡和数据卡用了和前面相同的卡片号外,题目卡、数据卡和注释卡的编排次序无关紧要,当注释卡重复时,只使用最后一张卡片。对于一组基本的卡片,建议将题目卡作为开始,接着按卡片号的次序放置数据卡。注释卡应能够自由地应用于文件输入。对于参数研究和改变方案的情况,新题目卡、插入卡、修改卡、消除数据卡和注释卡应放在终止卡的前面,这样很容易在为维持基本卡不变的情况下作修改。

当检查到卡片格式有错时,便在出错的字符下打印出包含美元符号‘$’的行和出错卡片列的信息,设置出错标记,并使输入处理继续进行。而SCDAP/RELAP5问题在输入处理结束时终止。当卡片中的错误被发现时,标准SCDAP/RELAP5错误信息将被打印出来(错误信息在********之前)。当程序要去处理错误的数据时,进一步的输入处理会导致另外的出错信息。

第二部分输入包括一个题目卡(可达100个字符)、可选择的注释卡以及数据卡,不用终止卡,也打印出这些输入卡的清单,这些卡片的顺序对这类输入是重要的。 A-1.3 题目卡

每个SCDAP/RELAP5问题的热工水力和气溶胶特性输入必须输入一张题目卡,题目卡以第一个非空格符号等号“=”作为标识。题目(题目卡上的其它符号)打印在输入数据列表的第二行上。若输入的题目卡不只一张,则用最后输入的那一张。 A-1.4 注释卡

当第一个非空格字符为星号(*)或美元符号($)时,即表示该卡为注释卡,所有空白卡片都作注释卡片处理。注释卡的处理是只打印它们的内容,注释卡可放在输入卡的任何位置,但不能放在继续卡之前。 A-1.5 数据卡

数据卡可以包含整数、实数(浮点),或字母数字中的各种数域。忽略数据前后的空格。数据卡上的第一个数域是该卡片的编号,编号必须是一个不带符号的整数。若第一个数域有错或不为整数,便给出一个出错标记。因此,当卡片上的数据不用时,程序将按卡片顺序号将其列在不用的数据卡片清单上。读完一张卡片号及其相应的数据后,便将该卡片号与前面输入的卡片号作比较。若发现有重复的卡片号,则用当前卡片上的数据代替前面已输入的具有相同卡片号的卡片上的数据。若输入的卡片上只有编号而无数据,则该卡片号和前面具有相同编号的卡片上的数据均被删除。删去一张不存在的卡片不认为是一个错误。若一张卡片造成数据的取代或删去,便打印出一个说明,指明该卡片是一张置换卡片。

在任一张数据卡上紧接着数据域之后可以用一个星号(*)或美元($)符号打头写出要注释的内容。

数域可以用一个数字(0到9),一个符号(+或-),或一个十进制的小数点(·)开头。用一个逗点或空格来终止数域(后面将会提到有一种例外)。数据由数值部分和选择性的指数部分组成。没有十进制小数点或指数的数域为整数域,带有一个十进制的小数点的数或指数,或两者兼有的数域为实数域。没有十进制小数点的实数假设在紧挨着第一位数字的前面有一个十进制小数点。指数部分表示以10为低的幂次,赋给数值部分。指数部分用一个E或D,一个符号(+或-)或两者兼有,后面再跟一个表10的幂次的数组成。实数的这些规则与在FORTRAN或F域中输入数据所用的规则相同,但不允许在字符之间留有空格(有一个例外)。可以读入用FORTRAN程序穿孔的实数据。为做到这点,指数D或E之后的空格被处理成正号。输入实数可以接受的形式如数12.45,有如下六种:

12.45,+12.45,0.1245+2,1.245+1,1.245E1,1.245E+1

字母域有三种形式。最常见的字母数字域以一个字母开头,以空格、逗点或卡末结束。在第一个字符之后除逗点和空格外的任何其他符号都是允许的。第二种形式是以引号(“)或撇号(’)为界的字符串。以引号或撇号作为域的开始,也用同样的符号作为域的终止。定界符号不属于字母数字的组成部分。若定界字符是域内所要求的字符,则两个相邻的定界字符便被处理为域内的一个字符。第三种字母数字域形式为nHz,其中n为域中字符的个数,域在z开始并扩展为n列。除了定界字符之外(即使是定界字符,若成对出现的话也是对的)。这后两种字域形式均可输入任何字符。在一个字内可以贮存的字符是八个,若字符数小于八个,该字向左看齐,其右边用空格填满。若要输入的字符多于八个,该域可通过若干字来贮存,每个字分配八个字符,最后一个字需要时间空格填满。无论何种形式的字母数字域,域与域之间必须用至少一个空格或逗号分开。

(Cray,Cyber 205,值得注意的是,对CDC-7600-6600级计算机每个字可贮存10个字符。

IBM等每个字贮存八个字符)。所有SCDAP/RELAP5要求的字母参数,如部件类型、系统名或处理选择等均被限制为八个字符。推荐用户使用每个字母参数均在八个字符以内,以便输入数据可用于任何类型的计算机。 A-1.6 继续卡

在卡片上的第一个非空格符号用加号(+)的,即表示该卡片上为继续卡,它可跟在一张数据卡或另一张继续卡的后面。每张卡片上的各个域必须是完整的,也就是说一个域不能开始于一张卡片而继续到下一张卡片上。每张数据卡或继续卡上都可有一个以星号或美元符号开始的注释域。继续卡上不输入卡片号,因为继续卡只不过扩展可以在一个卡片下输入的信息量。删去一张

卡片即删去数据卡及其有关的任何继续卡。 A-1.7 终止卡

每个RELAP5的输入数据都可用一张截断卡或一张句号卡来终止。截断卡和句号卡分别用一个截断号(/)或句号(.)来作为卡上的第一非空格符号。在这些卡片上的截断号或句号之后可以跟注释。

当用截断卡来作终止卡时,前一个问题作用的卡片号清单及有关数据留给了下一个问题。为下一个问题输入的卡片加在上一份清单上或作为置换卡,这要取决于卡片号。所形成的输入就如同到上一个句号卡或输入数据开始处为正面所有的截断卡都从输入数据中除去一样。

当用句号卡作为终止卡时,在下一个问题的输入被处理之前,前面所有的输入都被删去。 A-1.8 序列展开格式

几种不同类型的输入都规定用序列展开格式。这种格式由数据集组成,每一数据集包含一个或多个数据项,后跟一个整数。数据项是要展开的参数,而整数则是展开式的终点。展开式开始于比前一数据集的终点大1的点,并继续到本数据集的终点。对第一个数据集,展开式开始于1。各个终点一般是控制体数,接管数或网点数,并总是形成一个严格的上升序列。输入说明中将指明每个数据集的字数(至少为2)和最后的终止点。最后一个展开数据集的终点必须等于最后的终点。这里举两个例子来说明这个问题,对管道部件中控制体流动面积来说,NV个集合的序列展开格式是每个数据集两个字,若管道中的控制体数(NV)为10,则控制体流动面积可输入为:

0010101, 0.01, 10

在这种情况下,控制体1到10的流动面积的值为0.01,对NV个集合来说,管道控制体摩擦数据的格式为每个数据集三个字,可能的数据格式可以为

0010801 1.0-6, 0, 8, 1.0-3, 0, 9 0010802 1.0-6, -0, 10

这里,控制体1到3和控制体10具有相同的数值,而控制体9则具有另一不同的值。 A-1.9 上/下敏感性

以前的计算机系统仅允许上格式字母符号,下面的输入即为上格式输入。例如:SNGLOVL,1.25E5。现在,许多系统已经具有上和下格式字母符号,有一些应用有格式敏感性。在INEL,要求输入必须为下格式。用户对其它的安装应检查要求。对于安装在具有上和下格式能力的系统,有实用程序和编辑器方便地转换上或下格式成你所希望的格式。 A-1.10 数据卡的要求

在以下要给出的数据卡说明中,给出卡片号和说明该卡片数据的标题。然后说明包含在该卡片号内的任何变量数据,接着是给出数据的顺序、类型和数据项目的说明。类型说明中A表示字母数字串,I表示整数,R表示实数。 A-1.11 输入错误扑捉

在输入变量类型、卡片上词的数量、普通用途的范围和物理代码限制的同时会有一些相应的检查。作为输入的组成将进行进一步的检查。例如,一个持续的检查将检查基本的节点位置和校验基本的节点是否已经被放到材料界面上。

输入违背变量类型、词的数量、物理限制和连贯性的输入时将导致输入错误,但对于输入过程却不是这样。错误信息将被打印在输出文件上以“********”标出。如果输入是在正常使用的范围之外,一个警告信息将被打印在输出文件上以“$$$$$$$$.” 标出。为了在构建卡片和输入过程

中帮助用户,输入允许的选择范围将被用卡片输入描述的方式定义。对已给的输入变量的范围将用以下的方式定义。

正常类型——如果超出范围问题警告。

0.0 m < x < 2.0 m 强调——如果超出范围输入错误。

A-2 各类控制卡片

A-2.1 100卡片,问题类型和选择

这张卡片是必不可少的。

W1(A) 问题类型。输入下列选择之一:NEW,NEWSLP,RESTART,PLOT,REEDIT,STRIP

或CMPCOMS。

NEW或NEWSLP规定一个新模拟问题。若该程序没有与DEFINE SELAP选择一起进行编译,NEW问题输入NEW,没有SCDAP输入,并且可输入多个事件,若该程序与DEFINE SELAP一起进行编译,对RELAP5型输入数据输入NEW,对 SCDAP /RELAP5型输入数据输入NEWSLP。若输入了NEW,程序不希望在第一个问句或斜杠(/)终止卡后输入SCDAP并且可运用多种事件。若输入了NEWSLP,在第一张终止卡后希望输入SCDAP,并且不运用多种事件。RESTAT规定从先前问题的某一点利用RSTPLT文件获得的信息继续运行。PLOT规定从先前模拟运行的RSTPLT文件中给出结果。REEDIT还没有完成。STRIP规定从RSTPLT文件中提取数据,并且只有规定了的数据才写在STRIP文件中。CMPCOMS是对是一个或两个先前运行记录的文件进行的比较。

W2(A) 问题选择。当W1为NEW或RESTART时该参数是必须的。若W1为SPRIP,该参数

是可选的。若W1为NEW输入STDY-ST或TRANSNT来定义模型类型。问题选项从STDY-ST转变为TRANSNT时应注意的问题在A2.5节中讨论,反之亦然。当W1为SPRIP时,W2未输入时假定为BINARY,BINARY表示RELAP5/MOD2用户手册中描述的非格式化;W2也可输入FMTOUT,FMTOUT表示相同信息将以80列格式化记录。这个选择的一个作用是允许模拟结果可在不同类型计算之间进行传输。格式为: STRIP记录1. (5A8, 10X, A8) STRIP记录2. (A10, 3I10) STRIP记录3. (8A10) STRIP记录4. [A10, 7I10/(8I10)]

STRIP记录5---,N. [A10,5X,1P,4E15.6/(5E15.6)]

以上的STRIP记录涉及到非格式化文件的一种记录数据。STRIP记录3到N,可用来写多80列格式化记录。

A-2.2 101卡,输入检查或运行选择

对所有类型问题该卡片是可选的。

W1(A) 选择输入INP-CHK或RUN;若略去该卡片,则取RUN,若输入INP-CHK,则在输入

处理结束时问题终止;若输入RUN,在输入没有查出错误时就执行问题。 A-2.3 102卡,单位选择

该卡片供所有类型问题选用。若略去该卡片,则假设对输入和输出都用国际单位制(SI)。若使用该卡片,输入SI或BRITISH,SI单位是基本单位:kg,m,s等以及基本组合单位例如Pa

,ft,以及s,但压力是1bf/in2(1bf是磅力),热能是Btu,=kg·m/s2·m2。英制单位主要是1b(质量)

功率是MW。注意热导率和传热系数单位用s而不用h。 W1(A) 输入单位。

W2(A) 输出单位。若省略该参数,则输出为SI制。

A-2.4 103卡,再启动——输入文件控制卡

对除NEW以外的所有类型都需要这张卡片,不允许用于NEW型问题。当问题选择(卡片100中的W2)与再启动问题选择相同时,稳态或瞬态继续进行且RSTPLT文件里从头至再启动点的数据被保存下来。若从先前问题终止处开始再启动,再启动和绘图信息加在先前RSTPLT文件的尾部。若从先前问题的某一点开始再启动,从某点开始的再启动和绘图数据就代替原有的数据。若需要每一个模拟的RSTPLT文件,就需要将原RSTPLT文件拷贝一份保存起来。若问题选择不同,就不再保存至再启动点的数据,问题前进时间重新设置为零,且RSTPLT文件就象该问题类型是NEW一样包含信息。

通过改变问题选项从STDY-ST到TRANSNT(反之亦然)或者通过重新设定卡200的W1词使得问题前进时间发生变化时,将会观察到一些警告信息。这些都应该明确说明。当推进时间改变时,用户应该确保模型介入问题时间按照目标运作。受影响的模型包括:使用前进时间触发的trips,用时间作为操作数的控制系统(不包括对时间进行的微分或积分),使用时间作为相关变量查表和插值法。如果有必要,在再启动时,trips、控制系统、通用表格、时间相关控制体、接管和泵速表格都要重新再输入。STDY-ST to TRANSNT.在正常的模拟中,运行达到稳态需要包括前进时间在内的模拟特征量的较少使用,相应地也不需要在从STDY-ST到TRANSNT转变中花费太多精力。部分安全系统用延迟时间来触发,允许使用查表和插值法,对于瞬态运行必然涉及到频繁的多种变化,因为频繁使用时间逻辑会导致初始化失败。

W1(I) 再启动号。必须是再启动打印信息中打印的数号之一,与此号有关的再启动信息贮存

在RSTPLT文件中,若问题类型是STRIP,该号为零。

W2(A) 压缩标志。这个可选择的标志指示再启动——绘图文件是以压缩方式还是非压缩方式写

的。如果该词没输入或者输入NCMPRESS,再启动——绘图文件被认为是非压缩格式。如果输入CMPRESS,再启动——绘图文件被认为是压缩格式。

W3-7(A) 再启动——绘图文件名。这个可选择的数字输入能被用于进入再启动——绘图文件名。

一直到40个特征可能输入一个数字领域。(符号中心以五个八字符的单词对待这个域。) 缺省的再启动——绘图文件名是rstplt。无论是来自命令文件的缺省名还是来自以前情况的缺省名可能不被考虑。 A-2.5 104卡片,再启动——绘图文件控制卡

对NEW、RESTART和STRIP选择可以输入该卡片,对STRIP选择,用该卡片控制STRIP文件且不允许使用NONE选择。若略去该卡片,当问题结束时再启动——绘图文件系统,没有进一步的行动。用户可通过系统控制卡编排这些文件。为防止写入再启动——绘图文件,必须输入带NONE的卡片。

W1(A) ACTION。这个字可以不是空白格,若是NONE则不写再启动——绘图文件。

W2-6(A) 再启动——绘图文件名。这个可选择的数字输入能被用于输入再启动——绘图文件名。

一直到40个字符可能输入一个数字领域。(符号中心以五个八字符的单词对待这个领域。) 缺省的再启动——绘图文件名是rstplt。无论是来自命令文件的缺省名还是来自以前情况的缺省名可能不被考虑。这个信息只能被用于NEW问题;在RESTART问题中,这个信息能被用于103卡。 A-2.6 105卡,CPU时间保留卡

105卡片根据为作业保留的CPU时间来控制瞬态前进的终止。一些运行系统允许分配个作业的CPU时间可作为作业控制语句的一部分,并且提供在作业执行时一种确定CPU保留时间的方法。作为一种选择,这张卡的W3可作分配的CPU时间输入。一个可选的CPU保留时间是分配

的CPU时间减去程序测量到用去的CPU时间。若W3省去或为零,可选的CPU保留时间假定为无限长,在每一时间步长结束时为作业保留的CPU时间由系统的最小值和可选的CPU保留时间确定。如保留的CPU时间小于W1,瞬态立即终止。由于导致前进可能不在申请时间-长的终点的缩短,水力学、热传导和反应堆动力学可能没有前进到同一点,或前进可能不成功,准备采用减小的时间前长重做。强迫进行大编辑,小编辑,绘图编辑和再启动记录。如同问题尚未中断一样,瞬态可以从这点再启动。当在申请的时间前长上前进成功之后,并且CPU时间小于W2时,瞬态也中断,W2应该大于W1。W1和W2的缺省值为1秒或2秒。若没有输入本卡片或输入的数值小于缺省值,则用缺省值。同时也强使W2比W1大一秒。 时间值包括大编辑,小编辑,绘图以及任何其它跟随SCDAP/RELAPS执行结束后的处理所需的时间。这个量可选择性的,但是当系统无系统CPU限制时建议W3输入非零值。 W1(R) CPU保留限值1,S。 W2(R) CPU保留限值2,S。

W3(R) 分配的CPU时间(S)这个量是可选的。

若程序是与定义的编译时间选择CTSS一起进行编译的。W1输入零会引起无CPU结束检验以及可能在CPU时间终点发生CTSS正常终止,在这种情况下,问题可从去掉的文件中进行再启动。

A-2.7 110卡,非凝结气体种类

这张卡片对使用非凝结气SCDAP/RELAP5和RELAP5所有计算是必要的。对SCDAP/RELAP5问题必须包括氢气,对有安注箱的任何问题都必须包括氮气,在再启动问题中不能输入该卡片。

W1(A)-W5(A) 非凝结气类型。输入下列非凝结气体之一或二(最多为五):ARGON,HELIUM,

HYDROGEN,NITROGEN,XENON,KRYPTON,AIR或sf6。 A-2.8 115卡,非凝结气体和金属种类质量份额

若已输入了110卡片,且在110卡片中只输入了一种非凝结气体,否则该卡片是必要的。115卡片的参数必须等于110卡片的参数,在再启动问题中不能输入这个参数。 A-2.8.1 Card 115,非凝结气初始质量份额

W1(R)-W5(R) 每种非凝结气类型的初始质量份额。 A-2.8.2 Card 116,材料初始质量份额 W1-WN(R) 每种材料类型的初始质量份额。 A-2.9 118卡,传热控制卡

目前还未用到此卡。

A-2.10 120-129卡,水力学系统控制卡

独立水力学系统可由水力学部件输入来描述。独立水力学系统表示独立水力学系统之间无流动可能,一个典型的例子就是反应堆的一、二回路系统。一、二回路系统通过蒸汽发生器发生无流体接触的热交换,如果模拟一根破管,两个系统就不在是独立的,对每一个独立水力学系统进行处理列出每一个控制体的高度,并检查系统内的每个回路是否封闭。每个系统的参考控制体通过输入或缺省来建立。

这些卡片是可选择性的。若不输入该卡片,除非在水力学部件数据中规定了不同的流体,每

一个独立系统以水为流体且每一个系统最小号的控制体作为参考控制体。另外,参考控制体的缺省高度为零,若输入了这些卡片,在一张或多张卡片上对每一个独立系统输入一组或多组以四个参数为一组的参数,在再启动问题中不能输入这些卡片。 W1(I) 参考控制体号。必须是水力学系统的一个控制体。 W2(R) 参考高度(m,ft)。

W3(A) 流体类型,输入WATER,D2O或HYDROGEN。

W4(A) 输入编辑中使用的系统可选字母名,当不输入该参数时为“NONE”。

W6-9(A) 热力学特性系统文件名。这个可选的字母输入能被用于输入热力学特性系统文件名。

在一个字母域最多可输入三十二个名字。(符号中心以四个八特征的单词对待这个领域。) 这个热力学特性系统缺省的文件名是pfh20 for H2O and typfd2o for D2O。

W5(I) 系统信息标志。这个词有包装格式g,这个词是可选择的,如果没有输入,则g=0;g表

示系统中是否有非凝结气体出现,g=0表示系统中有非凝结气体出现,g=1表示系统中没有非凝结气体出现。 A-2.11 140-147卡,自我初始化选择控制卡

这些卡片是可选择性的。这些卡片提供的数据用来调用自我初始化选择。这些数据描述使用那些和多少控制器。为保持通用性和灵活性,自我初始化选择不要求稳态和几乎隐式求解方法选择同步进行,然而,这是推荐的过程,这些以后选择通过100卡片和201-299卡片来调用,对下面描述的数据卡片,用户必须完成A-14节描述的控制器数据。 A-2.11.1 140卡,自我初始化控制卡 这张卡片规定控制器类型和数目。 W1(I) 泵控制器数。

W2(I) 蒸汽流动控制器数。 W3(I) 给水控制器数。

A-2.11.2 141-142卡,自我初始化泵控制器和标识卡

这些卡片建立泵号和泵控制器号之间的关系。对引用的每一台泵,用户必须使用时间相关泵速选择。对泵部件卡CCC6100,参数2和3必须是作为泵控制器的字母部分和数字部分。应输入时间相关泵速数据(泵部件卡片CCC6100-CCC6199),以便自变量和泵可通过一条斜率为1的直线相关起来。

W1(I) 1号泵部件号。

W2(I) 1号泵控制器标识号。 W3(I) 2号泵部件号。

W4(I) 2号泵控制器标识号。

最多可输入6对泵、控制器数据。 A-2.11.3 143-144卡,自我初始化蒸汽流动控制器标识卡

这些卡片建立蒸汽流动控制阀门号和蒸汽流动控制器号之间的关系。 W1(I) 1号蒸汽流动控制阀门部件号

W2(I) 1号蒸汽流动控制阀门蒸汽流动控制器标识号 W3(I) 2号蒸汽流动控制阀门部件号

W4(I) 2号蒸汽流动控制阀门蒸汽流动控制器标识号

最多可输入6对控制阀门/控制器数据

注意,上面所述中是假定阀门部件为控制部件。然而用户还可使用泵或时间相关接管作为控制部件。

警告:只有伺服阀、时间相关接管或泵可作为控制部件,否则会导致诊断错误。 A-2.11.4 145-146卡,自我初始化给水控制器标识卡

这此卡片建立给水阀门和给水控制器号之间的关系。 W1(I) 1号给水阀部件号。

W2(I) 1号给水阀给水控制器标识号。 W3(I) 2号给水阀部件号。

W4(I) 2号给水阀给水控制器标识号。

最多可输入6对控制阀门/控制器数据。

注意,上面所中是假定阀门部件为控制部件。然而用户还可使用泵或时间相关接管作为控制部件。

警告:只有伺服阀、时间相关接管或泵可作为控制部件,否则会导致诊断错误。 A-2.11.5 147卡,压力和容积控制部件标识卡

这张卡片标明在自我初始化无效瞬态时,提供压力和容积控制的时间相关控制体的部件号。连接数据和压力水平。

W1(I) 替代稳压器的时间相关控制体部件号。

W2(I) 与上述时间相关控制体相连的部件号。警告:只允许单接管,否则会导致错误。 W3(R) 希望的稳态压力。

A-3 200-299卡 时间步长控制卡

A-3.1 200卡,初始时间值

这张卡片是可选择性的,若不输入,前进开始时的模拟时间为零。若输入了该卡片模拟时间就是输入值。该卡片只能用于NEW问题。 W1(R) 初始时间 必须大于或等于零。 A-3.2 201-299卡,时间步长控制

对NEW问题,至少要输入一张这种类型的卡片。若这组卡片是为再启动问题而输入的,则这组卡片便取代了再启动前的同类卡片,其它类型的问题不用这种卡片。卡号不必依次连续。 W1(R) 该组步长的结束时间(S)。此量必须随卡片号的增加而增加。 W2(R) 最小时间步长(S)。此量应是一个小于1.0E-6的正数。若输入了一个大于1.0E-6的数,

则重置为1.0E-6。

W3(R) 最大时间步长(S)。此量也称之为申请时间步长,在瞬态问题中(卡片100中W2=

TRANSNT)用户应当别使第一时间步长太大。

W4(I) 时间步长控制选择。此时具有ssdtt形式。ss代表0-15为数字,用来控制大编辑打印

内容。该数处理成一个2进制的四位数,若不设置任何数,表示该数为0,则给出全部标准大编辑的打印内容。若该数为1,则不打印热构件的温度;若该数为2,则不打印接管块的第二部分;若该数为4,则不打印控制块的第二部分;若该数为8,则不打印统计块。d代表0-7的数字,用来获得在每一水力学时间步长上的额外输出。这个数被处理成二进制的三位数。

若不设置任何数,表示该数为0,则得到在最大时间步长的标准输出。若该参数为零,在每一时间前长上都得到输出,而该二进制的位数表明得到的是哪种输出。若是1,则在每一时间前长得到大编辑,若是2,则得到小编辑,若是4,则在每一时间步长上写出绘图记录。由于产生的打印量很大,因此对这些选择应慎重使用。这些额外输出只在当前运行时生成,不写到RSTPLT文件中。tt代表0-15的数字,用来控制时间步长。推荐的方法是,对于半隐式水力学系统tt=3,对几乎隐式系统tt=11,该数被处理成一个二进制的四位数,若不设置任何数,表示该数为0,则不用误差估计时间前长控制,并试图降最大时间步长(W3)用于水力学和热构件前进。

然而由于某种原因如水物质性的失败,水力学时间步长将下降到材料迁移极限,甚至其进一步下降到最小时间步长。若该数为1,传热用最大时间步长,水力学步长除在tt=0中所描述的时间步长控制外,还将通过质量误差分析,使其被控制在最小与最大时间步长之间。若该数为2,热构件时间步长与水力学步长相同。若该数为4,传热用最大时间步长,水力学步长除在tt=0中所描述的时间前长控制外,还将使用部分隐式水力学和热壁的偶合。若该数为8,传热用最大时间步长,水力学步长除在tt=0中所描述的时间步长控制外,还将使用几乎隐式水力学数字关系(见另两段有关tt设置的限制)。

除在特定的检验场合,不推荐使用tt=0,若最大时间步长选得足够小,能保证水力学与热传导/传热计算间的显示关系维持稳定,可以使用tt=1。若有怀疑,则用tt=3,这是推荐的用来运行大多数半隐式水力学关系计算。对于大多数几乎隐式水力学关系计算,推荐tt=11。

W5(I) 小编辑和绘图频率。每两个小编辑和写出绘图信息到所的最大或申请时间步进数。

W6(I) 最大编辑频率。每两个编辑所隔的申请时间步进数。

W7(I) 再启动频率。每写入一次再启动信息所隔的申请时间前进数。

A-4 301-399卡片,小编辑要求

这些卡片对NEW和RESTART问题是可选择的。对REEDIT问题是要求的,对PLOT和STRIP问题是不允许的。若不输入这些卡片,无任何小编辑打印输出。输入这些卡片后,小编辑生成并按申请卡片顺序打印出各量。每张卡片输入一项申请,卡片号不必依次连续。在RESTART问题中,若输入了这些卡片,先前输入的卡片全部取消。

4.1-4.7节中列出的量总在再启动绘图文件中。4.8节中列出的量只有在2080XXXX使用时才生成在再启动-作图文件中。 W1(A) 变量代码。 W2(I) 参数。

下面列出可编辑的量和所需要的输入,为方便起见,列出绘图申请和TRIP规格中可能用到的量做为表中的自变量,以及控制语名中的运算量。同时给出这些量的单位。A-6节中描述的交互式输入变量可与下面列出的变量以相同方法用于批作业中。交互式输入变量的参数是1000000000。变量TRIP中相比较的量必须具有相同的单位。而输入到由变量申请代码规定的表中的量必须具有指定单位。 A-4.1 常用量

代码 量

CPUTIME 本问题的当前CPU时间(S)。参数为零。 COUNT 当前努力发展的有价值的数。参数为0。 DT 当前时间步长(s). 参数为0。

DTCRNT 当前Courant时间步长(s),参数为0.

ERRMAX 切断的错误质量份额的当前估计。参数为0.这是两个类型的电脑质量错误中的最大值(εm or εrms)。

EMASS 估计质量误差(kg,1b)。参数为零。

NULL 规定空域。只允许用于TRIP卡。参数为零。

SYSTMS 系统中的蒸汽,水和非凝结气体的总质量。参数是系统数字n.

STDTRN 稳态、瞬态标志。参数为0. 对稳态,数值是 0.0. 对瞬态数值是1.0. SYSMER 系统中的质量错误估计(kg, lb). 参数是系统数字n. TESTDA 一个20个的测试数据序列, [real testda(20)] 为了方便程序的升级而定义。输入参

数从1到20(parameter). 初始值为0.而且过程必需插入设置的测试数值。通常的目的是在小编辑或绘图打印中允许一个简单的信息调试方式。

TIME 时间(S)。参数为0。这种规格不能用于小编辑申请。 TIMEOF 发生TRIP的时间(S)。参数为TRIP号。这种规格只允许用于TRIP卡。 TMASS 所有系统中水蒸汽和非冷凝气体的总质量(kg,1b)。参数为零。 A-4.2 与部件有关的量

下面列出的量是专门用于确定部件的。例如,仅对泵部件才能请求泵转速。参数为部件号,即在输入卡中的三位数CCC号。 代码 量

ACPGTG 储水箱蒸汽的定压比热, Cp, 蒸汽温度 (J/kg.K, Btu/lb.oF)。 ACPNIT 储水箱非凝结气的定压比热, Cp, 蒸汽温度(J/kg.K, Btu/lb.oF)。

ACQTANK 储水箱中通过传热传质传给气体的总能量(W,Btu/s)。

。 ACRHON 储水箱非冷凝气体密度(kg/m3,1b/ft3)。 ACTTANK 储水箱平均金属壁面温度(K,oF)

。 ACVLIQ 储水箱垂直管及波动管中的液体体积(m3 ,ft3)。 ACVDM 储水箱垂直管及波动管中的气体体积(m3 ,ft3)

ACVGTG 储水箱蒸汽的定容比热, Cv, 蒸汽温度 (J/kg.K, Btu/lb.oF)。 AHFGTF 储水箱在液态温度下加热汽化。(J/kg, Btu/lb)。 AHFGTG 储水箱在蒸发温度下加热汽化。 (J/kg, Btu/lb)。 AHFTG 储水箱在蒸发温度下液态焓。(J/kg, Btu/lb)。 AHGTF 储水箱在液态温度下的蒸发焓。(J/kg, Btu/lb)。 AVGTG 储水箱在蒸发温度下的特殊焓(m3/kg, ft3/lb)。 AVISCN 储水箱非凝结气体的粘性 (kg/m.s, lb/ft.s)。 BETAV 储水箱中饱和蒸汽的膨胀系数(K-1, oF-1)。 CDIM GE 机械干燥剂注入湿度质量。 DIM 机械注入量。

DMGDT 储水箱内定部蒸汽质量交换的时间频率 (kg/s, lb/s)。 GDRY GE 机械分离能力因子。 OMEGA 惯性阀角速度。 (rad/s, rev/min)。 PMPVEL 泵部件中的泵转速(rad/s,rev/min)。

。 PMPHEAD 泵部件中的泵压头(Pa,1bf/in2)

PMPTRQ 泵部件中的泵转矩(N·m,1bf·ft)。 PMPMT 泵的马达轴矩 (N.m, lbf .ft)。 PMPNRT 计算泵惯性 (kg.m2, lb.ft2)。

TURPOW 汽轮机部件中发展的功率(W,Btu/s)。

。 TURTRQ 汽轮机部件中发展的转矩(N·m,1bf·Ft3)

TURVEL 汽轮机部件的角速度(rad/s,rev/min)。 THETA 惯性阀角位置 (deg)。 TUREFF 汽轮机部件效率。

VLVAREA 阀门部件中的阀门面积比。这是局部打开阀物理面积与接管面积之比。

VLVSTEM 阀部件中相对阀杆位置,这是局部打开物理面积与全开物理阀门面积之比。 XCO GE机械分离液体的携带量。 XCU GE机械分离蒸汽的携带量。 XI GE 机械分离的进口质量。 A-4.3 与控制体有关的量

对下面的变量代码,参数是控制体号,即在大编辑打印中的九位数CCCNN0000。 代码 量

AVOL 控制体面积(m2, ft2)。参数是控制体字F。

BETAFF 热膨胀液体等压系数, βf, 体积条件 (K-1, oF-1)。 BETAGG 热膨胀液体等压系数, βf, 体积条件(K-1, oF-1)。

。 BORON 硼密度(kg/m3,1b/ft3·s)

Btu/lb.oF)。 CSUBPF 液体的比热,Cpf,大多数条件 (J/kg.K,

CSUBPG 蒸汽的比热,Cpg,大多数条件(J/kg.K, Btu/lb.oF)。 DRFDP ρf对应压力的偏导(s2/m2, s2/ft2)。

DRFDUF ρf对Uf的偏导 (kg.s2/m5, lb.s2/ft2)。 DRGDP ρg对应压力的偏导(s2/m2, s2/ft2)。

DRGDUG ρg对Uf的偏导(kg.s2/m5, lb.s2/ft2)。 DRGDXA ρg对Xn的偏导(kg/m3, lb/ft3)。

DSNDDP 体积条件下的蒸汽焓(J/kg, Btu/lb)。 DTDP   Ts对应压力的偏导(K/Pa, in2·oF/lbf)。 DTDUG Ts对Ug的偏导 (s2·K/m2, s2·oF/ft2)。 DTDXA Ts对Xn的偏导(K, oF)。

DTFDT Tf对应的压力的偏导(K/Pa, in2·oF/lbf)。 DTFDUF Tf对Uf的偏导Uf (s2·K/m2, s2·oF/ft2)。 DTGDP Tg对应的压力的偏导(K/Pa, in2·oF/lbf)。

DTDUG Tg对Ug的偏导(s2·K/m2, s2·oF/ft2)。

o

F)。 DTGDXA Tg对Xn的偏导 (K,

FLOREG 流动工况号。参数是控制体数加F。

FWALF 液体壁面摩擦系数(kg/m3·s, lb/ft3·s); 该参数为控制体数加F。 FWALG 蒸汽壁面摩擦系数(kg/m3·s, lb/ft3·s); 该参数为控制体数加F。

GAMMAC 对显式的热传导/传递和流体力学之间的耦合,这个值为0。对于隐式的热传导/传

递和流体力学之间的耦合,这是贴近壁面处边界层内汽液界面每单位体积传热速率(kg/m3?s, lb/ft3?s)。

GAMMAI 泡状流汽液产生/冷凝,在汽/液界面上单位体积质量传递速率(kg/m3?s, lb/ft3?s)。 GAMMAW 对显式的热传导/传递和流体力学之间的耦合,这是贴近壁面处蒸汽产生/冷凝,边

界层内汽液界面每单位体积传热速率。对于隐式的热传导/传递和流体力学之间的耦合,这是贴近壁面处蒸汽产生,边界层内汽液界面每单位体积传热速率(kg/m3?s, lb/ft3?s)。

HGF 单位体积直接加热的加热系数(W/m3?K, Btu/s?ft3?oF). HIF 单位体积液面传热系数 (W/m3?K, Btu/s?ft3?oF)。 HIG 单位体积蒸汽传热系数 (W/m3?K, Btu/s?ft3?oF)。 HVMIX 液体和蒸汽的焓 (J/kg, Btu/lb).

。 P 控制体压力(Pa,1bf/in2)

PECLTV Peclet数。

PPS 蒸汽分压力(Pa,1bf/in2)。 Q 控制体总热源(W,Btu/s)。 QUALS 控制体静态含汽量。

QUALA 控制体不冷凝气体质量份额。 QUALE 控制体平衡态含汽量。

QWG 控制体对蒸汽的热源(W,Btu/s)。

。 RHO 总密度(kg/m3,1b/ft3)。 RHOF 液体密度(kg/m3,1b/ft3)。 RHOG 蒸汽密度(kg/m3,1b/ft3)

。 SATHE 饱和条件下根据蒸汽分压得出的液体比焓(J/kg, Btu/lb)。 SATHG 饱和条件下根据蒸汽分压得出的蒸汽比焓(J/kg, Btu/lb)

。 SATTEMP 控制体饱和温度(K,oF)

SIGMA 表面张力 (N/m, lbf/ft)。 SOUNDE 控制体音速速率 (m/s, ft/s)。

TEMPF 控制体液体温度(K,oF)。

。 TEMPG 控制体蒸汽温度(K,oF)

THCONF 液体热导率 (W/m?K, Btu/s?ft?oF)。 THCONG 蒸汽热导率(W/m?K, Btu/s?ft?oF)。 TSATT 总压力下的饱和温度 (K, oF)。 UF 液体比内能(J/kg,Btu/1b)。 UG 蒸汽比内能(J/kg,Btu/1b)。

。 VAPGEN 单位体积内总质量流率(kg/m3·s,1b/ft3·s)

VELF* 与控制体有关的液体速度(m/s,ft/s)。 参数为控制体数加F。 VELG* 与控制体有关的蒸汽速度(m/s,ft/s)。参数为控制体数加F。 VISCF 液体粘度 (kg/m?s, lb/ft?s)。 VISCF 蒸汽粘度 (kg/m?s, lb/ft?s)。 VOIDF 液体空泡份额。 VOIDG 蒸汽空泡份额。 VOIDLA 水位上面空间。 VOIDLB 水位下面空间。 VOLLEV 控制体内水位 (m, ft)。 VVOL 控制体的体积 (m3, ft3)。 A-4.4 与接管有关的量

对以下的变量申请代码,参数是接管号,即编辑打印中的九位数CCCNN0000。 代码 量

C0J 接管分配系数。C0J中的0是数字零而不是字母O。

CHOKEF 接管壅塞标志。如果流动不发生壅塞值为0,若存在壅塞流则为1。 FIJ 两相间的摩擦(N?s2/m5, lbf?s2/ft5)。 FJUNFT 前向总不可逆损失的形阻系数。 FJUNRT 反转总不可逆损失的形阻系数。 FLORGJ 接管流动区域数字。

FORMFJ 液体损失因子 (无量纲)。 FORMGJ 蒸汽损失因子 (无量纲)。 FWALFJ 无限大液体壁面摩擦系数。 FWALGJ 无限大蒸汽壁面摩擦系数。 IREGJ 垂直泡状流/塞状流流型区。 MFLOWJ 汽液两相混合物流率(kg/s,1b/s)。 QUALAJ 接管不凝结气体质量份额。

。 RHOFJ 接管液体密度(kg/m3,1b/ft3)。 RHOGJ 接管蒸汽密度(kg/m3,1b/ft3)

SONICJ 接管声速(m/s, ft/s)。

UFJ 接管液体比内能(J/kg,Btu/1b)。 UGJ 接管蒸汽比内能(J/kg,Btu/1b)。 VELFJ 接管液体速度(m/s,ft/s)。 VELGJ 接管蒸汽速度(m/s,ft/s)。 VGJJ 汽相飘逸速度(m/s,ft/s)。 VOIDFJ 接管液体空泡份额。

VOIDGJ 接管蒸汽空泡份额。

VOIDJ 接管蒸汽份额,用于界面拽力。 XEJ 接管平衡态含汽量。 A-4.5 与热构件有关的量

对申请代码HTVAT,参数是七字节热构件号CCCGONN.对其他申请代码,参数是七字节热构件号带一个二字节的附加代码。对除HTTEMP外的其余代码,左边界代码是00,右边界代码是01.对HTTEMP,附加代码是网格点号。在RSTPLT文件上的绘图记录只写表面温度。因此,除非通过2080XXXX卡片将内部温度强行写到RSTPLT文件中,绘图型问题中的绘图申请和STRIP请求只限于表面温度。 代码 量

HTGAMW 单位体积壁面蒸汽产生率 (kg/m3?s, lb/ft3?s)。 HTVAT 热构件体积平均温度(K,oF)。

。 HTRNR 热流密度(W/m2,Btu/s·ft2)

。 HTCHF 临界热流密度(W/m2,Btu/s·ft2)。 HTHTC 传热系数(W/m2·K,Btu/s·ft2·oF)

。 HTTEMP 网格点温度(K,oF)

HTMODE 边界传热模数 (无单位)。

HTRG 传至汽相的热通量 (W/m2, Btu/s?ft2)。 PECL 热构件,液体皮克雷特数。 STANT Stanton数。 A-4.6 反应堆动力学量

反应堆动力学量的参数是零 代码 量

RKPOWA 反应堆衰变功率(W)。

RKTPOW 反应堆总功率,即裂变与裂变产物衰变功率之和。 RKFIPOW 反应堆裂变功率(W)。

RKGAPOW 反应堆裂变产物衰变功率(W)。 RKREAC 反应性(dollars)。

。 RKRECPER 倒周期(S-1)A-4.7 控制系统量

参数是控制部件号,即在输入卡片中的三字节号CCC或四字节号CCCC。

代码 量

CNTRLVAR 控制部件号。这些量除SHAFT部件外均假设是无因次。AGAZ A-4.8 扩大编辑绘图变量

在A-4.8.1至4.8.4中列出了一些可能在小编辑,绘图申请,控制系统和逻辑TRIP中要用到的额外变量。 除非用户输入了2080XXXX,否则在再启动——绘图文件中不写入这些额外申请变量。对需要在再启动——绘图文件中写入的额外申请变量就通过2080XXXX卡片输入。用户可以规定1到9999个这样的变量写入在启动——绘图文件中。 这些额外变量可以按常规方法用在小编辑卡、TRIP卡片控制系统卡片和绘图申请卡片。

下面的卡片可使要申请的变量写在RSTPLT文件上,在前面提到的一些变量申请代码(见A-4.1到A-4.7)中不需要这些卡片。 2080XXXX

W1(A) 变量申请代码 见A-4.8到A-4.84有效申请代码。 W1(A) 参数输入与变量申请代码有关的参数。 A-4.8.1 一般量

代码 量

COUNT 当前尝试前进count数。参数为零。 DT 当前时间步长(S),参数是零。

,参数是零。 DTCRNT 当前Courant时间步长(S)

ERRMAX 当前估计截断误差。参数为零。

STDTRN 稳态/瞬态标识。参数是零。对于稳态,值是0.0,对于瞬态,值为1.0 。 TESTDA 20个量的测试矩阵,以方便编程者。 A-4.8.2 与部件相关的量

下面列出的一些量是仅对某些特定部件的。如只有泵部件才能申请泵转矩,与之相关的参数是部件号,即输入卡片中的三字节CCC号。 代码 部件类型 量

AHFGTF 安注箱 液体温度下的汽化热(J/kg,Btu/1b)。 AHFGTG 安注箱 蒸汽温度下的汽化热(J/kg,Btu/1b)。 AHFTG 安注箱 蒸汽温度下的液体焓(J/kg,Btu/1b)。

。 ACPGTG 安注箱 蒸汽温度下的蒸汽定压比热Cp(J/kg·K,Btu/1b·0F)。 ACVGTG 安注箱 蒸汽温度下的蒸汽定容比热Cv(J/kg·K,Btu/1b·0F)

AVISCN 安注箱 非凝结气粘度(kg/m·s,1b/ft.s)。

。 ACPNIT 安注箱 蒸汽温度下不凝气体定压比热Cp(J/kg·k,Btu/1b·0F)

AHGTF 安注箱 液体温度下的蒸汽焓(J/kg,Btu/1b)。

。 BETAV 安注箱 饱和蒸汽膨胀系数(K-1,oF-1)

DMGDT 安注箱 汽鼓蒸汽质量变化率(kg/s,1b/s)。 OMEGA 惯性阀 阀门角速度(rad/s,rev/min)。 PMPMT 泵 泵马达转矩(N·m,1bf·ft)。

。 PMPNRT 泵 计算的泵转矩(惰性)(kg·m2,1bf·ft2)

THETA 惯性阀 阀门角位置(deg)。 A-4.8.3 与控制体相关的量

对以下变量代码,参数是控制体号,即打印在输入卡片中的九字节CCCNN0000。 代码 量 AHTCOFG

,该参数为控制体数加F。 AVOL 控制体面积(m2,ft2)

。 BETAFF 液体等压热膨胀系数(K-1,0F-1)。 BETAGG 汽体等压热膨胀系数(K-1,0F-1)

F)。 CSUBPF 大多数条件下液体比热CP(J/kg·K, Btu/lb·o

。 CSUBPG 大多数条件下蒸汽比热CP(J/kg·K, Btu/lb· oF)

。 DSNDPP 声速到压力的偏导(m2·s/kg,ft2·s/1b)

DRFDP RHOF对压力的偏导(s2/m2,s2/ft2)。

。 DRFDUF RHOF对Uf的偏导(Kg·s2/m5,1b·s2/ft5)。 DRGDP RHOG对压力的偏导(s2/m2,s2/ft2)

。 DRGDUG RHOG对Ug的偏导(Kg·s2/m5,1b·s2/ft5)。 DTFDP Tf对应的压力的偏导(K/Pa,in2·0F/1bf)。 DTFDUF Tf对Uf的偏导(s2·K/m2,s2·0F/ft2)。 DTGDP Tg对压力的偏导(K/Pa,in2·0F/1bf)。 DTGDUG Tg对Ug的偏导(s2·K/m2,s2·0F/ft2)

。 DTGDXA Tg对Xn的偏导(K,0F)

。 DTDP 饱和温度Tsat对相应压力的偏导(K/Pa,in2·0F/1bf)

。 DTUG Tsat对Ug的偏导(s2·K/m2,s2·0F/ft2)

。 DTDXA Tsat对Xn的偏导(K,0F)

FLOREG

,该参数为控制体数加F。 FWALF 液体与壁面摩擦力系数(kg/m3·s,1b/ft3·s)

,该参数为控制体数加F。 FWALG 蒸汽与壁面摩擦力系数(kg/m3·s,1b/ft3·s)。 GAMMAW 单位体积壁面蒸汽产生率(kg/m3·s,1b/ft3·s)。 HTCOFF 壁面和液体的传热系数(W/m2·K,Btu/s·ft2·0F)。 HTCOFG 壁面和蒸汽间的传热系数(W/m2·K,Btu/s·ft2·0F)。 HIF 单位体积液侧表面传热系数(W/m3·k,Btu/s·ft3·oF)。 HIG 单位体积蒸汽侧表面传热系数(W/m3·k,Btu/s·ft3·0F)

。 PPS 蒸汽部分压力(Pa,1bf/in2)

。 RHOM 质量误差检查的总密度(kg/m3,1b/ft3)。 RGDXA RHOG对Xn的偏导(kg/m3,1b/ft3)

SATHF 饱和条件下液体比焓(J/kg,Btu/1b)。 SATHG 饱和条件下蒸汽比焓(J/kg,Btu/1b)。

。 SIGMA 表面张力(J/m2,Btu/ft2)

。 THCONF 液体热导率(W/m·k,Btu/s·ft·0F)。 THCONG 蒸汽热导率(W/m·k,Btu/s·ft·0F)

TSATT

VISCF 液体粘度(kg/m·s,1b/ft·s)。 VISCG 蒸汽粘度(kg/m·s,1b/ft·s)。 VVOL

A-4.8.4 与接管相关的量

对以下的变量代码,参数是接管号,即打印在大编辑中的九字节CCCNN0000。 代码 量

C0J 接管分布系数,C0J中的0是数字0,不是字母O。

。 FIJ 相间摩擦(N·s2/m5,1bf·s2/ft5)

FLORGJ 接管流动区域号。

FORMFJ 流体形阻损失因子,无因次。 FORMGJ 蒸汽形阻损失因子,无因次。

IREGJ 垂直泡状/团状流接管流动区域号。 SONICJ 接管声速(m/s,ft/s),这个速度是基于实际接点面积,它并没有考虑喉部比率和流

量系数的影响。

VOIDJ 接管蒸汽空泡份额(用在相间摩擦力)。 VGJJ 蒸汽飘移速度(m/s,ft/s)。 XEJ 接管平衡态含气量。 A-4.8.5 与热构件相关的量

代码 量

HTMODE 边界传热模型号(无单位),模型号指明那个传热区域在起作用。参数是七字节热

构件几何体号CCCGONN加上附加的两字节号,附加的两字节00表示左连界,01表示右连界,这个量对再淹没热构件同样有效。

HTRG 对蒸汽相的热流密度(W/m2,Btu/s.ft2)参数是热构件几何体号

CCCG0NN加上附加的两字节号(00表示左连界,01表示右连界)。

HTGAMW 单位体积壁面蒸汽产生率(kg/m3·s,1b/ft3·s)参数是热构件几何体号CCCGONN加

上附加的两个字节号(C00表示左连界,01表示右连界)。 A-4.8.6 与再淹没相关的量

对以下的变量代码,参数是热构件几何体号,即七字节号CCCG0NN。

代码 量

。 TCHFQF 与QFCHFN相对应的温度(K,0F)

。 TREWET 再湿温度(K,0F)

。 QFHTCN 临界传热系数(W/m2·K,Btu/s·ft2·0F)。 QFCHFN 临界热流密度(W/m2,Btu/s·ft2)

ZTRWT CHF点位置(m,ft)。

A-5 400-799卡片或20600000-206200000卡片 TRIP输入数据

这些卡片对NEW和RESTART问题是选择性的,但不能用于其它类型问题。TRIP数据输入有两种卡片系列,但在一个问题中只能使用一种卡片输入系列。461-799卡允许输入199个变量TRIP和199个逻辑TRIP。20600010-20620000卡片允许输入1000个变量TRIP和1000个逻辑TRIP。 A-5.1 400卡,TRIP取消卡

此卡片只允许用于RESTART问题。它可使再启动前的问题中的全部TRIP消除,任何所需要的TRIP必须重新输入。

W1(R) Discard 任何其它输入均为错误。 A-5.2 206000 00卡,TRIP卡片系列类型。

若去掉该卡片,选择401-599卡为变量TRIP和601-799卡为逻辑TRIP。TRIP号等于卡片号。若输入了该卡片,卡片号206NNNN0来输入TRIP数据,NNNN是TRIP。TRIP号1-10000表示变量TRIP。TRIP号101-2000表示逻辑TRIP。TRIP号不必依次连续。 W1(A) EXPANDED 任何其它输入均为错误。

A-5.3 401-599卡或20600010-20610000卡,变量TRIP卡

每一个卡片定义一个关于随时间变化量的逻辑语句或TRIP条件。若TRIP条件不满足,则TRIP为FALSE(假)或不置,否则TRIP条件为TRUE。再启动时,引入新TRIP,旧TRIP可以删除。与旧TRIP号相同的新TRIP取代旧TRIP。

变量代码参数与在A-4节中对小编辑的描述相同。当只要求与常数进行比较时,允许将NULL用于右边。以TRIP号为参数的变量代码TIMEOF表示最近一次满足TRIP的时间。

W1(A) 变量代码 对再启动问题,这个参数也包含DISCARD或RESET。DISCARD消除TRIP。

而RESET则置TRIP为FALSE(假)。若输入DISCARD或RESET,则在该卡片上就不再输入其它参数。

W2(I) 参数

W3(A) 关系符。可以是EQ,NE,GT,GE,LT或LE,这些符号具有标准的FORTRAN意义。注意和

FORTRAN不同,这里不用问号。

W4(A) 变量代码。 W5(I) 参数。

W6 (R) 附加常数。

W7(A) 锁指示。若为L,则一旦TRIP为TRUE(真)便维持不变,即使后来的条件不满足亦如

此。若为N,则每一时间前长都要检验TRIP。

W8(R) TIMEOF量(S) 该参数是可选的。若输入该参数,所有TRIP均初始化为假,TIMEOF量

设置为-1.0。若输入了-1.0,TRIP初始化为FALSE(假)。若TIMEOF输入了零或一个正数,TRIP初始化为TRUE。在NEW问题中,TIMEOF不能大于零。在RESTART问题中TIMEOF不能大于再启动时间。

逻辑语句是:参数1和参数2给出的量以及参数4和5给出的量加参数6之间是否满足参数3给出的关系?若关系是FALSE,则TRIP是FALSE或是不置,若关系是TRUE,则TRIP是TRUE或置。若TRIP是FALSE,则TIMEOF变量是-1.0,若TRIP是TRUE,则TIMEOF便是该TRIP最近一次置TRUE的时间。一个锁住的TRIP从不再置,一旦它变成与-1.0不同的数,则TRIP时间将保持不变。对非锁TRIP,在TRIP条件变为FALSE之间,TRIP时间保持不变,变为FALSE以后TRIP时间再次变为-1.0,若TRIP条件再次变为TRUE,过程反复进行,对象时间检验那一类TRIP,应当用L来消除反复检验。显然若用N,其结果也没有什么错误或差别。

A-5.4 601-799卡或20620010-20620006卡逻辑TRIP卡

若要输入这些卡片,则必须至少已输入一张变量TRIP卡,每张逻辑TRIP卡定义了这类卡片中或变量TRIP卡片中所定义的各种TRIP之间的逻辑关系。

W1 (I) TRIP号 这个号的绝对值必须是变量TRIP或逻辑TRIP定义的一个TRIP号。一个

负的TRIP号表示在检验中使用TRIP状态的反值。

W2(A) OPERATOR 算子可以是AND,OR或XOR。对再启动问题,这个参数还可以包括

DISCARD或RESET。DISCARD消除TRIP,而RESET 将TRIP置为FALSE,若输入了DISCARD或RESET,则在该卡片上将不输入其它的参数,而W1可以是零。

W3(I) TRIP号 类似于W1。

W4(A) 锁指示 锁指示若为L,则TRIP量为真以后保持不变。若为N,则在每

一时间前长上检验TRIP

W5(R) TIMEOF量(S) 该参数是可选择性的。若不输入,TRIP初始化为FALSE(假),

(假)。若输入了0或一个正数,TIMEOF量设为-1.0.若输入-1.0则TRIP初始化为FALSE

TRIP初始化为TRUE。对 NEW问题TIMEOF不能大于零。对再启动问题TIMEOF不能大于再启动时间。

TRIP条件由逻辑表达式结果给出:W1的TRIP 条件算子 W3的TRIP条件。

A-5.5 600卡,终止前进TRIP卡

该卡片可在NEW和RESTART问题中输入。可输入一或二个TRIP号。若任何一个指示的TRIP为TRUE,则终止前进。这些TRIP来保证在检验时间时为真。 W1(I) TRIP号。

W2(I) TRIP号 第二个TRIP号不必输入。

A-6 801-999卡 交互式输入数据

当程序与核电站分析程序(NPA)软件结合起来时,程序具有交互式和彩显功能。这个功能可使用户在彩色绘图终端上查看结果和修正自定义输入量。用户可在模拟同时输入命令和查看一种增进理解瞬态现象格式的SCDAP/RELAP5输出。交互式输入加上TRIP和控制系统功能,可使用户象运行员一样操作,如打开/关闭阀门,启动/停止/改变泵速以及改变运行功率等。

在批作业或交互式作业时可输入这些数据。在NEW或RESTART作业中可输入这些卡片,在再启动作业中,他们增加或代替再启动问题中的数据。

当作业交互式运行时只需卡片定义那些在执行时通过CRT数据输入可变的变量。卡片输入定义输入变量名和初始值。这些变量名即使在拼法相同时有也完全独立于SCDAP/RELAPS程序中使用的FORTRAN变量名。列在A-4 节中的变量可作为用户自定义变量来使用。因此,用户自定义变量可用在TRIP,控制变量语句。某些表中的自变量,小编辑中的编辑变量以及绘图。适当的输入,交互式用户就像一个反应堆运行人员影响变化。如打开/关闭/调节阀门或设置控制器新的运行点。当输入这些自定义变量名时,变量名是申请代码的字母部分,1000000000是数字部分。 W1(A) 变量名 输入变量名或在RESTART作业中输入DELETE取消变量。 W2(R) 初始值。若W1输入了DELETE就不必输入这个参数。

交互式执行时,直到在终端改变初始值时一直使用初始值。这个值可在任意时刻按照需要进行改变。一个或多个变量可通过CRT成对输入变量名和值进行改变。例如VLV1=0 VLV2,1 VLV3 0,POWER=3050+6,式中VLV1,VLV2,VLV3和POWER是用户自定义名,格式与卡片数据输入相同。注意,等于符号被处理为结束符号,输入值应为浮点量,但整数值被转换成浮点值。NPA连接体也允许在模拟时期用其他更方便的方法输入新值。

W3(R) 以用户自定义单位输入的W2或任何终端输入的代换值,当他们用于比较计算时应转

换成SI单位。用户单位只能用于输入交互式变量与控制系统变量相容时。该参数若非零,为转换因子;该参数若为正,转换式为:V(转换量)=V(输入量).W3.若为负, V(转换量)=V(输入量)/1.8-W3。当温度从F转换成K时,W3应为-255.3722222。若省略该参数,转换因子缺省为1.0.若该参数为零,令两个参数必须包括一个变量申请代码。恰当的转换因子由程序提供。若使用英制单位,程序也提供了相应的转化因子。

W4(A) 变量申请代码字母部分不能使用CNTRLVAR. W5(A) 变量申请代码证书部分若为零可省略。

A-7 CCCXXNN卡,水动力学部件

这些卡片是新题型(NEW)所需要的,并且可以进入再启动题型(RESTART)。在NEW题型里描述一个水力学系统,在再启动(RESTART)题型里,这个水动力学系统可以通过部件删除、加入或替代加以修改。最后形成(Resultant)的问题至少要描述两个控制体和一个接管。水力学卡号分成几个域,其中CCC是部件号(部件号不必依次连接),XX为卡片类型,NN为一类型中的卡片号。当卡片范围指定时,则其号不必依次连续。 A-7.1 CCC0000卡,部件名和类型

这个卡片是每个部件都需要的。

W1(A)部件名。采用说明系统部件用途的名称,对CDC7600计算机,最多只可用10个字符,

对多数其他计算机例如Cray机,Cyber205和IBM机最多只可用8个字符。

W2(A)部件类型。输入下列部件类型之一:

SNGLVOL,TMDPVOL,SNGLJUN,TMDPJUN,PIPE,ANNULUS,BRANCH,SEPARATR,JETMIXER,TURBINE,ECCMIX,VALVE,PUMP,MTPLJUN,ACCUM或指令DELETE。这个指令DELETE只允许用于RESTART题里,并且这部件号必须是再启动时刻存在的一个部件。指令DELETE会删去这个部件。每个部件的其余卡片取决于部件的类型。 A-7.2 单一控制体部件

单一控制体在CCC0000卡里用UNGLVOL表示。接管连接码确定了该控制体取向部件的进口或出口可以接一个以上的接管,如果一个端部无接管,认为那个端部是一个封闭端。通常只有分支部件才有一个以上的接管与控制体的一个端部相连。 A-7.2.1 CCC0101至CCC0109卡,单一控制体几何卡

这个卡是单一控制体所需要的,可在一张或几张卡片上输入九个字码,卡片号不必依次连续。 W1(R) 控制体流通面积。 W2(R) 控制体长度。

。三W3(R) 控制体的容积。程序要求这个容积等于控制体流通面积乘上长度(W3=W1×W2)

个量W1,W2和W3中至少应有两个为非零。如果三个量中一个为零,那么其值将由其他两个计算出来。如果三个量都不为零,那么容积必须等于流通面积乘上长度,相对误差需在0.000001以内。

W4(R) 方位角。这个角度绝对值必须小于等于360o的一个正值。这个量不用于计算,而是标

定用来可能的自动作节点流程图用。

W5(R) 倾角。这个角度绝对值必须小于等于90o。角度零度表水平方向,正角度表向上倾斜,

即入口处于最低位置,这个角度在相间阻力计算中要用到。

W6(R) 高度变化。正值表高度增加,这个量绝对值必须小于或者等于控制体长度,如果垂直

角为零,那么这个量必须为零。如果这垂直角为非零,那么这个量必须也为非零,且具有相同符号。

W7(R) 壁面粗糙度。

W8(R) 水力直径。如果为零,则这个水力直径由2×(控制体面积/π)12算得,程序要校核

管子粗糙度是否小于水力学直径的一半。

W9(R) 控制体控制标识。这个字码取组合格式pvbfe。这数字p规定水程序包用到还是不用。

P=0规定这个控制体要用水程序包,p=1规定这个控制体不用水程序包。在模拟稳压器时推荐用水程序包。

数字v规定用不用垂直分层模型。0用,1不用。

数字b指定所用的相间摩擦模型。b=0意味着将要用管相间摩擦模型,b=1表示将用棒束相间摩擦模型。

数字f指定要不要计算壁面摩擦。0计算,1不计算。

数字e指定用非平衡态还是用平衡态。0非平衡,1平衡。平衡态控制体不应该跟不平衡态控制体相接。平衡态这种选择只用于跟其他程序比较。 A-7.2.2 CCC0200卡,单一控制体初始条件

该卡片对单一控种码设置的流体。

W1(I) 控制字码 这个字码取组合格式εbt。

数字ε指定流体。0为缺省流体,1为指定水,2为指定重水,3为氢,缺省流体是由120到129卡为这水动力学设置的流体或在这水动力学系统另一个控制体里出现的这个控制字码设置的流体。在120至129卡设置的流或这些控制字码设置的流体类型必须一致。如果120至129卡不输入且所有控制字码用缺省值0,那么就假定水为这种流体。

数字b指定硼是否存在,0不包含,1指定硼浓度,硼量比液态水量。在其他所需要的热力学信息之后,输入硼浓度。

数字t表示下列字码是如何被用来确定初始的热力学状态。输入t=0至3表示只有一组分。输入t=4至6允许标定双组分。如果t=0那么其后的四个字码理解为压力,液体比内能,汽相比内能和蒸汽空泡份额。这些量根据这控制体控制标识确定它们是属非平衡工况还是平衡工况,如果平衡工况,则要校核静力学含汽量;为确定热力学状态只用到压力和内能。

如果t=1,那么其后两个字码理解为处于平衡态中温度和含汽量。 如果t=2,那么其后两个字码理解为平衡态工况下的压力和含汽量 如果t=3,那么其后两个字码理解为平衡态工况下的压力和温度

下面这些选择范围所用的准则为:

1.0E-9<含汽量<0.99999999,属两相工况其它两种情况属单相工况 不可冷凝选择为:

如果t=4,那么其后三个字码理解为压力(Pa, lbf /in2),温度(K, oF),和平衡态含汽量。用这种输入选择及含汽量大于0.0且小于等于1,就会得到饱和不可冷凝工况,而且这温度限制在输入压力对应的饱和温度以下,置含汽量为0.0被用作为一个标识,即要将控制体初始化到全部为不可冷凝气工况而不带温度限制。用这个干不可冷凝含气选择可将含汽量重新设置为1.0.

如果t=5,那么其后的三个词理解为温度(K, oF),含汽量和平衡态不可冷凝含汽量。平衡和不可冷凝汽量被限制在1.0E-9至0.99999999之间。

如果t=6,那么其后四个字码理解为压力(Pa, lbf /in2),液相比内能(J/kg, Btu/lb),汽相比内能(J/kg, Btu/lb),汽相空泡份额和不可冷凝含汽量。汽相空泡份额和不可冷凝含汽量组合必须是热力学一致的,如果不可冷凝含汽量为0.0,那么不可冷凝工况不存在,输入

处理就转入没有不可冷凝那类的处理分支,如果不可冷凝含汽量置为1.0,那么汽相泡份额必定也为1.0。当汽相空泡份额和不可冷凝含汽量都置为1.0时,则控制体温度用输入的汽相比内能从不可冷凝能量方程计算出来

W2-W6(R)在字码W1下所说明的量,根据控制字码可能需要两至五个量,只输入所需要的最

小个数数字码,如果要输入硼浓度的话,硼浓度接在表热力学工况所需最后一字码的后面。

A-7.3 时间相关控制体部件

这个部件由TMDPVOL指示为两个字码在卡 CCC0000上。对大编辑,小编辑和绘图变量时间相关控制部件被标为CCC010000

A-7.3.1 CCC0101N至CCC0109卡,时间相关控制体几何卡

这个卡是时间相关控制体所需要的,九个字码可在一张或几张卡上输入,卡片号不必依次连续地。

W1(R) 控制体流通面积。 W2(R) 控制体长度。

W3(R) 控制体的容积。程序要求这个容积等于控制体流通面积乘上长度(W3=W1×W2)。三

个量W1,W2和W3中至少应有两个为非零。如果三个量中一个为零,那么其值将由其他两个计算出来。如果三个量都不为零,那么容积必须等于流通面积乘上长度,相对误差需在0.000001以内。

W4(R) 方位角。这个角度绝对值必须小于等于3600的一个正值。这个量不用于计算,而是标

定用来可能的自动作节点流程图用。

W5(R) 倾角。这个角度绝对值必须小于等于900,角度零度表水平方向,正角度表向上倾斜,

即入口处于最低位置,这个角度在相间阻力计算中要用到。

W6(R) 高度变化。正值表高度增加,这个量绝对值必须小于或者等于控制体长度,如果垂直

角为零,那么这个量必须为零。如果这垂直角为非零,那么这个量必须也为非零,且具有相同符号。

W7(R) 壁面粗糙度。

W8(R) 水力直径。如果为零,则这个水力直径由2×(控制体面积/π)12算得,程序要校核

管子粗糙度是否小于水力学直径的一半。

W9(R) 控制体控制标识。这个字码取组合格式pvbfe。这数字p规定水程序包用到还是不用。

P=0规定这个控制体要用水程序包,p=1规定这个控制体不用水程序包。在模拟稳压器时推荐用水程序包。

数字v规定用不用垂直分层模型。0用,1不用。

数字b指定所用的相间摩擦模型。b=0意味着将要用管相间摩擦模型,b=1表示将用棒束相间摩擦模型。

数字f指定要不要计算壁面摩擦。0计算,1不计算。

数字e指定用非平衡态还是用平衡态。0非平衡,1平衡。平衡态控制体不应该跟不平衡态控制体相接。平衡态这种选择只用于跟其他程序比较。 A-7.3.2 CCC0200卡,时间相关控制体数据控制字码

这个卡是时间相关控制体所需要的

W1(I) CCC02NN卡上时间相关数据的控制字码。这个字码取组合格式εbt。

数字ε指定流体。0为缺省流体,1为指定水,2为指定重水,3为氢,缺省流体是由120到129卡为这水力学设置的流体或在这水动力学系统另一个控制体里出现的这个控制字

码设置的流体。在120至129卡设置的流或这些控制字码设置的流体类型必须一致。如果120至129卡不输入且所有控制字码用缺省值0,那么就假定水为这种流体。

数字b指定硼是否存在,0不包含,1指定硼浓度,硼量比液态水量。在其他所需要的热力学信息之后,输入硼浓度。

数字t表示下列字码是如何被用来确定初始的热力学状态。输入t=0至3表示只有一组分。输入t=4至6允许标定双组分。如果t=0那么其后的四个字码理解为压力,液体比内能,汽相比内能和蒸汽空泡份额。这些量根据这控制体控制标识确定它们是属非平衡工况还是平衡工况,如果平衡工况,则要校核静力学含汽量;为确定热力学状态只用到压力和内能。

如果t=1,那么其后两个字码理解为处于平衡态中温度和含汽量。 如果t=2,那么其后两个字码理解为平衡态工况下的压力和含汽量 如果t=3,那么其后两个字码理解为平衡态工况下的压力和温度 下面这些选择范围所用的准则为:

1.0E-9<含汽量<0.99999999,属两相工况,其它两种情况属单相工况。 不可冷凝选择为:

如果t=4,那么其后三个字码理解为压力(Pa, lbf /in.2),温度(K, oF)和平衡态含汽量。用这种输入选择及含汽量大于0.0且小于等于1,就会得到饱和不可冷凝工况,而且这温度限制在输入压力对应的饱和温度以下,置含汽量为0.0被用作为一个标识,即要将控制体初始化到全部为不可冷凝气工况而不带温度限制。用这个干不可冷凝含气选择可将含汽量重新设置为1.0.

如果t=5,那么其后的三个词理解为温度(K, oF),平衡态含汽量和不可冷凝含汽平衡和不可冷凝汽量被限制在1.0E-9至0.99999999之间。

如果t=6,那么其后四个字码理解为压力(Pa, lbf /in.2),液相比内能(J/kg, Btu/lb),汽相比内能(J/kg, Btu/lb),汽相空泡份额和不可冷凝含汽量。汽相空泡份额和不可冷凝含汽量组合必须是热力学一致的,如果不可冷凝含汽量为0.0,那么不可冷凝工况不存在,输入处理就转入没有不可冷凝那类的处理分支,如果不可冷凝含汽量置为1.0,那么汽相泡份额必定也为1.0。当汽相空泡份额和不可冷凝含汽量都置为1.0时,则控制体温度用输入的汽相比内能从不可冷凝能量方程计算出来。

W2(I) 表触发号,这个字码是选择性的。如果不出现或为零且W3不出现,则不用触发,时

间变量就是步进时间,如果为非零而W3不出现,则这个数就是触发号。如果这触发为假则时间变量为-1.0,如果触发为真,则时间变量为步进时间减去触发时间。

W3(A) 变量请求码的字母部分。这个量是选择性的。如果存在,则这个字码和下一个字码为

一个变量请求码,它指定用来表的查寻和内插的检索变量。如果触发号为零,则要用这指定的变量。如果触发号为非零,则若触发为假时取这个触发逻辑与这个字码省略时的触发逻辑是不同的。

W4(I) 变量请求码的数字部分,如果不存在则就假定为零。 A-7.3.3 CCC0201至CCC0299卡,时间相关控制体数据卡

这些卡是时间相关控制体部件所需要的。卡号不必依次相连,但是后面数组中检索变量必须等于或大于先前组中的值。允许输入一组或几组数据,最多可到5000组。一组数据是由这检索变量及随在他后面的由CCC0200控制字码指定的要求数据组成。如果这检索变量值位于输入检索变量之间,则要用线性内插。如果这变量值超出表值范围,则用端点值。如果要求为常数值,则只需要一组数据。当只进入一组数据时计算机时间就缩短了。对阶跃变化可以这样来处理,输入相信的两个数据组,它们的检索变量相同或只有极其微小的差别。若有两个完全相同的变量值,则

选择的这个数据组将是最接近于先前变量值的那一组。每张卡片可以输入一组或几组数据,也可以分隔开来输入数据。字码的总数必须为组多少的倍数。

在输入时间相关控制体表其中检索是由其他某一部分里的一个热力学变量时,如果这部件编号是这样的,即这时间相关控制体在这个控制体提供所需的检索变量以前就初始化了则会遇到麻烦。这个问题的一个可靠解决是使这检索变量成为按要求单位表示一控制系统输出,而这热力学变量是程序内部单位表示的控制系统输入,这样就能将这控制系统初始值置到检索变量的所要求的初值上,而这初值将为这时间相关表用到。 A-7.4 单一接管部件

单一接管部件是由CCC0000卡SNGLJUN来指定的。 A-7.4.1 CCC0101至CCC0109卡,单一接管几何卡

这个卡是单一接管部件所要求。

W1(I) 来向部件连接代码。这指明一个部件,接管坐标方向是从这个部件出来的,对于连接到

时间相关控制体情形,这连接代码为CCC00000.其中CCC为这个时间相关控制体的部件号。连接其他控制体可以用一种老格式也可以用一种扩展的格式。用老格式时,如果是跟部件的人口侧相连,则用CCC000000,如果是跟部件的出口侧相连则用CCC010000。在老格式中,W6用来指定横向连接。用扩展格式,则连接码为CCCVV000N,其中CCC为部件号,VV为控制体号,N指定端面号。一个不为零的N指明这是个扩展格式。N等于1和2分别指定了这个控制体座标方向的入口和出口截面,N等于3至6则指明了横向流。目前的横流模型没有要求进出口朝向,但是在将来的版本中N等于3和4将指定第二个座标方向的入口和出口截面,N等于5和6将指定第三个座标方向的入口和出口端面。因为在扩展格式中横流是直接指定的,因此W6中横流标识(flag)在输入中可以不顾而在输出编辑中要恰当地加以设置。注意在处理管部件的控制体来说,老格式和扩展格式之间在能力上有一个重要的差别。用老格式连接只用可能是跟第一个相关控制体的入口或横流面或最后一个相关控制体的出口或横流面。用扩展格式,连接可以跟任何一个相关制制体的任何面之间进行。输出编辑用扩展格式不管其输入格式如何。

W2(I) 去向部件连接代码。这指定一个部件,这接管座标方向终止于这个部件。见上W1的描述。

。如果为零,则这面积置为相邻的两个控制体的最小的那个控制体面W3(I) 接管面积(m2,ft2)

积,对于面积由天然变化情形,接管面积必须等于或小于相接的控制体面积的最小的一个。对于面积平滑变化的情况,没有什么限制。

W4(R) 正向流动能量损失系数。 W5(R) 反向流动能量损失系数。

W6(I) 接管控制标识。这个字码取组合格式fvcahs.

数字f指定CCFL选择。f=0表示CCFL模型不会被用到,f=1表示CCFL模型要用到。 数字v指定水平分层夹/带抽出选择,v=0表示不用这个模型,v=1表示朝上接管,v=2表朝下接管,v=3表位于中心侧面接管。

数字c指定壅塞选择。c=0表明要用壅塞模型,c=1表示不用壅塞模型。 数字h指定非均相还是均相。h=0指定非均相(两个速度动量方程)。H=2指定均相选择(单一速度动量方程)。对于均相选择(h=2)情形,大编辑打印将显示1。

数字s指定正常还是横向流接管。s=0指定一正常的接管,管s=1指定一横流接管,并且指定去向控制体是一个横流控制体,s=3指定一个横流接管并且指定来向和去向两个控制体都是横流控制体。

W7(R) 欠热的排放系数。这个量只用于欠热液体壅塞流计算。这个量必须大于零且小于等于2.0。

如果不存在则置为1.0。

W8(R) 两相排放系数。这个量只用于两相壅塞流计算,这个量必须大于零且小于等于2.0。如

果不存在则置为1.0。

W9(R) 过热排放系数。这个量只用于过热蒸汽壅塞计算。这个量必须大于零且小于等于2.0。

如果不存在则置为1.0。 A-7.4.2 CCC110卡,单一接管直径及CCFL数据卡

注:从老数据卡片组转换来说需要阅读此卡。

这张卡片是选择性的。如果这张卡仅仅只用来指定相间阻力计算所用的接管水力直径的话,那么字码1应该输入这个直径,字码2-4应该进入其他任何允许的值(这个不会用到)。

如果这个卡用来指定CCFL模型,那么用以合适指定CCFL模型的四个字码全部要输入。 W1(R) 接管水力直径,Di(m,f t)这个量是接管水力直径,用在CCFL关系方程和相间摩擦中,必

须大于等于零。如果进入零或缺省值,则这接管直径有下式算得:2.0×(接管面积/π)0.5 W2(R) 淹没关系式形式,β0若为零,用WAllis的CCFL形式。如果为1则用Kutstelanze的CCFL

形式,若在零与1之间,则在Wallis KutateladzeCCFL形式之间用Bankoff加权,这个数

必须大于等于0且小于等于1。缺省值为1.

W3(R) 气体截距,C。这个量是用在CCFL关系式中的(当HF2=0)气体截距,它必须大于零。W4(R) 斜率,m。这个量是用在CCFL关系式中的斜率,必须大于零。缺省值为1。 A-7.4.3 CCC0201 卡单一接管的初始条件

这个卡是单一接管不见所要求的。

W1(I) 控制字码,若为零,下面的两个字码为速度。若为1,则下面的两个字码是质量流量。

W2(R) 初始液体速度或质量流量,这个量或为速度(m/s,f t/s)或为质量流量(kg/s,1b/s),取决于上述的控制字码。

W3(R) 初始蒸汽速度或质量流量,这个量或为速度(m/s,ft/s)或为质量流量(kg/s,1b/s),取决

于上述控制字码。

W4(R) 相间速度(m/s,f t/s),输入零。 A7.5 时间相关接管部件

这个部件由TMDPJUN指示为两个字码在卡 CCC0000上。对大编辑,小编辑和绘图变量时间相关接管部件被标为CCC010000

A-7.5.1 CCC0101 卡,时间相关接管几何卡

W1(I) 来向部件连接代码。它指定这样一部件,这接管座标方向朝向是从这个部件开始(出发)。

对跟一时间相关控制体连接情形,其连接代码为CCC000000。此中CCC为这时间相关控制体的部件号。可以用老格式也可以用扩展的格式来跟其他控制体相接。用老格式,如果连结是跟部件的进口侧,则用CCC000000,如果控制体出口侧相连,则用CCC010000。用老的格式,它不可能指定一个横向流连接。用扩展的格式,连接代码为CCCVV000N,其中CCC为部件号,VV为控制体号,N指明表面号。一个非零N指定了扩展格式。N等于1和2分别指定控制体座标方向的进口和出口表面,N等于3到6指定横向流。目前横流模型不要求进出口朝向,在将来版本中,N等于3到4将指定第二个座标轴方向的进

1口和出口表面,N等于5和6将第三个座标轴方向的进口和出口表面。因为在扩展格式中横向流是直接加以指定的,因此W6中的横流标识在输入中将忽略了,但是在输出编辑中适当地加以设置,注意:在处理管部件控制体时老的和扩展格式之间在能力上有一个重要的区别。用老的格式,连接只可能跟第一个管控制体的入口或横流表面,或最后一个管控制体的出口或横流表面,而用扩展格式连接可以跟任何管控制体的任何表面。输出编辑不管输入格式如何皆用扩展格式。

W2(I) 去侧部件连接代码。这指定这样一个部件,接管座标方向终止于这个部件,建上述对W1

的描述。

。若为零,则面积设置为两个相邻控制体的最小的那个面积,对时间相W3(R) 接管面积(m2,ft2)

关接管,接管面积没有什么限制。 A-7.5.2 CCC0200卡,时间相半接管控字码

这个卡式选择性的,若这个卡不存在,则这时间相关数据中的第二和第三个字码就假定为速度。

W1(I) 控制字码,若为零,则CCC0201-CCC02999卡中的时间相关数据中的第二和第三个字码

为速度,若维1,则CCC0201-CCC0199卡中的时间相关数据中的第二和第三个字码为质量流量。

W2(I) 表触发号,这个字码是选择性的,如果不存在或为零,且W3不存在,则不用触发,且其

时间变量为步进时间。若为非零且W3不存在,这个数就是触发号,在触发为假设时间变量为-1.0,如果触发其为真时,时间变量为步进时间减去触发时间。

W3(A) 变量请求码的字母部分,这个量是选择性的。如果存在,则这个字码和下面的字码使是一

变量请求码,他指定表查阅和插值用的检索变量。如果触发号位零,则始终要用这指定的变量,如果触发号非零,如果触发为假,则用-1.0E75,如果触发为真,则用这指定的变量。可以选择TIME,但是需要注意其触发逻辑与省略这个字码的触发逻辑是不相同的。

W4(I) 变量请求码的数字部分,如果不存在就假定为零。 A-7.5.3 CCC0201至CCC0299卡,时间相关接管数据卡

这些卡是时间相关接管部件所要求的。卡片号不必依次相连,但后续的数据组中检索变量的值必须等于或大于以前一组的值。可以进入一组或几组数据,最多可达100组。每组有检索变量,液体速度(m/s,f t/s)或质量(kg/s,1b/s)蒸汽速度(m/s,f t/s)。或质量流量(kg/s,1b/s)和界面速度(m/s,f t/s)组成。对界面速度项输入量,选择速度还是质量取决于A-7.5.2中控制字码W1的值,时间相关数值用的内插和卡片格式与A-3.3节完全一样。 A-7.6 管型或环型部件

管型部件和环型部件在CCC0000卡上分别由PIPE和ANNULUS指明的。管型部件和环型部件是类似的,只是环型部件必须是垂直的,当呈环雾状流工况时全部的水以膜态存在(即无液滴)。对两个部件的其余输入是完全一样的。入口和出口可以跟一个以上的接管相接。如果一端无接管与其相接,则该端就认为是一个封闭端。输入一个管型部件或环型部件所需的各种卡片的讨论下面给出来。这里讨论假定管型部件至少有两个控制体和一个接管把两个控制体分离开来。输入一个控制体的管型部件或环型部件也是可能的。为了实施这种特殊情形,用户必须设置控制体数并且把控制体卡上控制体数置为1。此外,用户不应该输入任何接管卡。 A-7.6.1 CCC0001卡,管型或环型部件信息卡 这个卡式管型部件所要求的。

W1(I) 控制体数,NV.NV必须大于零,且小于100。管型部件内部相关接管数为NV-1。外部接

管用其他部件来描述。 A-7.6.2 CCC0101至CCC01999卡,管型或环型控制体面积

格式为每组两个字码,按序列展开格式进入,共NV组,这些卡片是要求的但卡片号不必依次相连。每个组字码为:

。 W1(R) 控制体流通面积(m2,ft2)

W2(I) 控制体号。

A-7.6.3 CCC0201至CCC02999卡,管型或环型接管流通面积

这些卡是选择性的,如果输入,则卡号不必依次相连。格式是每组两个字码,按序列展开格式进入,共有NV-1组。

。如果卡片不存在或一个字码为零,则这关流通面积置为相W1(R) 内部接管流通面积(m2,ft2)

邻控制体最小那个流通面积。对面积突然变化的情形,则接管面积必须等于或小于相邻控制体的最小的那个面积,对面积平滑变化情形,没有什么限制。

W2(I) 接管号。

A-7.6.4 CCC0301至CCC03999卡,管型或环型控制体的长度

这个卡是管型部件所要求的,格式为每组两个字码,按序列展开格式进入,共有NV组。卡号不必依次相连。

W1(R) 管控制体长度(m,ft)。 W2(R) 控制体号。

A-7.6.5 CCC0401 至CCC0499卡,管型或环形控制体的容积

其格式为每组两个字码按有序格式输入,共NV组。卡号不必依次相连。

。如果这些卡不存在,那么就假定容积等于零。程序要求每个容积等于W1(R) 容积(m2,ft2)

流通面积乘和长度。对任何控制体三个量面积,长度,容积中至少有两个量为零。如果其中有一个为零,那么这个量将由其他两个量算得。如果没有一个量为零则容积必须等于面积乘长度其相对误差在0.000001以内。

W2(I) 控制体号。

A-7.6.6 CCC0501至CCC0599卡,管型或环形控制体(水平)角

这些卡片是选择性的,如果不输入的话,则其水平角度就设置为零。水平角在计算中没有用到,但是对能够的自动作节点要进入此角,格式为每组两个字码,按序列展开格式进入,共NV组,卡号不必依次相连。 W1(R) 方位角(度)。这个角的绝对值必须小于等于360度。 W2(I) 控制体号。

A-7.6.7 CCC0601至CCC0699卡,管型或环形控制体垂直角

这些卡是管型部件所要求的,其格式为每组两个字码,按序列展开格式进入,共NV组。卡号不必依次相连。 W1(R) 倾角(度)。这个角度的绝对值必须小于等于90度。角度零为水平方向,角度正角表

向上朝向,即出口标高比如口的高。这个角度用在相间摩擦计算中。

W2(I) 控制体号。

A-7.6.8 CCC0701至CCC0799卡,管型或环形控制体高度变化

这些卡是选择性的,如果这些卡不存在,则高度变化由控制体长度乘以垂直角的正弦计算而得。卡片格式为每组两个字码,按有序展开格式进入,最多可达NV组。卡片好不必依次相连。 W1(R) 高度变化(m,ft),正值为高度上增加。其量值必须等于或小于控制体长度。如果垂

直角朝向为零,则高度变化也必定为零。如果垂直角为非零,则高度变化量也必定为非零,具有与垂直角同样的符号。

W2(I) 控制体号。

A-7.6.9 CCC0801至CCC0899卡,管型或环形控制体摩擦系数

这些卡是管型部件所要求的。卡片格式是每组3个字码,其NV卡号不必依次相连。 W1(R) 壁面粗糙度(m,ft)。 W2(R) 水力直径(m,ft)。若为零,则水力直径由2.0*(控制体面积/π)0.5计算得到。程序

要校核,粗糙度是否少于水力直径的一半。

W3(I) 控制体号。

A-7.6.10 CCC0901至CCC0999卡,管型或环形控制体损失系数

这些卡是选择性的,如果不存在则能量损失系数就置为零。卡格式为每组3个字码,共NV-1组,按序列展开格式进入,卡号不必依次相连。 W1(R) 正向流动能量损失系数。 W2(R) 反向流动能量损失系数。 W3(I) 接管号。

A-7.6.11 CCC1001至CCC1099卡,管型或环形控制体控制标识

这些卡是管型控制体所要求的。卡格式为每组两个字码,共NV组,按序列展开格式进入,卡号不必依次相连。

W1(I) 控制体控制标识,这个字码取组合格式pvbfe。

数字p指定水程序包永不用到。P=0指定控制体要用水程序包(water packing scheme)。P=1指定控制体不用水程序包。当模拟稳压器时推荐用水程序包。

数字v指定垂直模型永不用到。V=0指定控制体要用垂直分层模型。V=1指定控制体不用垂直分层模型,在模拟稳压器时推荐用水程序包。

数字b指定要用界面摩擦模型,b=0意味着要用管内界面摩擦模型。b=1意味着要用棒来束界面摩擦模型。

数字f指定壁面摩擦是否要计算,f=0指定控制体的壁面摩擦效应要加以计算。f=1指定控制体的壁面摩擦效不要加以计算。

数字e指定用非平衡态还是平衡态,e=0指定要用非平衡态(不相等的温度)计算,e=1指定要用平衡态(相等的温度)计算,平衡态控制体不应跟非平衡态控制体相连,这平衡态选择只供用来同其它程序作比较用。

W2(I) 控制体号。

A-7.6.12 CCC1101至CCC1199卡,管型或环形接管控制标识

这些卡是管型部件要求的。卡格式为每组两个字码,共NV-1组,按序列展开格式进入,卡号不必依次相连。

W1(I) 接管控制标识,这个字码取组合格式fvcahs。

数字f指定CCFL选择,f=0意味着不用CCFL模型,f=1意味着用CCFL模型。

数字v没有用到,应该输入为零(v=0)。

数字c指定壅塞选择。c=0意味着要用壅塞模型,c=1意味着不用壅塞模型。

数字a指定面积变化选择。a=0意味着面积平滑变化或没有变化。a=1意味着面积突然变化。

数字h指定非均相或均相模型,h=0指定非均相模型(双速动量方程组)选择。h=2指定均相模型(单一速度动量方程)选择。对均相选择(h=2),大编辑打印将显示1。 数字s没有用到,应该输入为零。

W2(I) 接管号。

A-7.6.13 CCC1201至CCC1299卡,管型或环形控制体初始条件

这些卡是管型部件要求的。卡格式为每组7个字码,共NV组,按序列展开格式进入,卡号不必依次相连。

W1(I)控制码。这个字码取组合格式εbt。

数字ε指定流体,ε=0为缺省流体。ε=0指定水,ε=2指定D2O(重水),ε=3指定氢。缺省流体是120至129卡水动力字系统摄定的流体或是这水动力学系统中另外一个控制体的这个控制字码设定的流体,120至129卡上设置的流体类型或者由这些控制体字码设定的流体类型必须是一致的(即不能指定不同的流体)。如果120至129卡片没有进入,且所有控制字码用缺省值ε=0,那么就假定水作为流体。

数字b指定硼是存在还是不存在,数字b=0指定控制体流体不含硼,b=1指 定在其他所要求的热力信息进入以后进入硼浓度,它以硼量比液态水量表示 (可以为零)。

数字t指定下列字码是如何被用来确定初始的热力学状态的。进入t=0至3指定单组份(蒸汽/水)。进入t=4至6允许指定双组份(蒸汽/水和不可冷凝气体)。如果t=0其后四

、液体比内能(J/kg,Btu/1b)、蒸汽的比内能(J/kg,个字码被理解为压力(Pa,1bf/in2)

Btu/1b)。和汽相空泡份额。这些量被理解为处于非平衡工况还是平衡工况要看控制体控制标识。如果处于平衡状态,则要校核静态含量。但是只用压力和内能来限定这热力学状态。W6应该为零。

如果t=1,则其后两个字码理解为压力(K,F)和处于平衡工况下的含汽量。W4,W5和W6应该为零。

如果t=2,则其后两个字码理解为压力(Pa,1bf/in2)和处于平衡工况下的含汽量。W4,W5和W6应该为零。

。如果t=3,则其后两个字码理解为压力(Pa,1bf/in2)和处于平衡工况下的温度(K,F)

W4,W5和W6应该为零。

下面选择只用于不可凝气体中,无论哪种情况,用以确定含汽量值范围的判据为:

1.0E-9≤含汽量≤0.99999999属两相工况,含汽量<1.0E-9或含汽量>0.99999999属单相工况 不可冷凝选择为:

,温度(K,F)和平衡态含汽量,用如果t=4,那么其后3个字码理解为压力(Pa,1bf/in2)

这种输入选择及含汽量大于零且小于等于1.0将会得到饱和的不可冷凝工况。W5和W6应该为零。还有要把这温度限制在比输入压力相应的饱和温度低。设置含汽量0.0被用作为一个标识,即这控制体初始化到全部不可凝工况(干不可凝工况)而不带温度限制,用于干不可凝工况选择将含汽量重新设置成1.0。

如果t=5,则其后的三个字码理解为温度(K,F)平衡态含汽量不可凝含汽量。平衡态含汽量和不可凝含汽量都要限制在1.0E-9和0.99999999之间。

W5和W6应该为零。

如果t=6其后五个字码被理解为(Pa,1bf/in2),液体比内能(J/kg,Btu/1b)蒸汽的比内能(J/kg,Btu/1b),汽相空泡份额和不可凝含汽量。汽相空泡份额和不可凝含汽量的组合必定是热力学一致的。如果不可凝含汽量设置为0.0,则不可凝气体不存在,输入处理就转入无不可凝气体的那种类型处理。如果不可凝气体存在(不可凝含汽量大于0.0),那么汽相空泡份额必定不为零,如果不可冷凝气体含汽量设为1.0(纯不可凝工况),即末汽相空泡份额也一定为1.0。当汽相空泡份额和不可冷凝含汽量都设置为1.0时,其控制体温度用输入的气体比内能通过不可冷凝能量方程来算得。

W2-W6(R) 字码W1所说明的量,必须进入5个量,对不用的量应该进入零,如果控制字码

(W1)指明硼存在,那么必须输入CCC2001至CCC2099卡以限定硼出示浓度,在W2至6中不输入硼浓度。

W7(I) 控制体号。

A-7.6.14 CCC2001至CCC2099卡,管型或环形初始浓度

这些卡只有在CCC1201至CCC1299卡片中控制字码之一(W1)指定为硼时才有要求,卡格式为每组两字码共NV组,按序列展开格式进入。每个控制体必须输入硼浓度,对其控制字码没有指定硼的那些控制体应该进入零。 W1(R)硼浓度(硼量比液态水量)。 W2(I)控制体号。

A-7.6.15 CCC1300卡,管型或环形接管工况控制字码

这个卡式选择性的,如果不存在,则CCC1301至CCC1399卡上的数据假定为速度。

W1(I) 控制字码。若为零,则CCC1301至CCC1399卡每组数据第一,第二个字码为速度。

若为1,则CCC1301至CCC1399卡上每组数据第一,第二个字码为质量流量。 A-7.6.16 CCC1301至CCC1399卡,管型或环形接管初始条件

W1(R) 初始液体速度或质量流量(速度以m/s,ft/s计,质量流量以kg/s,1b/s计)。 W2(R) 初始重气速度或质量流量(速度以m/s,ft/s计,质量流量以kg/s,1b/s计)。 W3(R) 界面速度(m/s,ft/s),输入零。 W4(I) 接管号。

A-7.6.17 CCC1401至CCC1499卡,管型或环形接管直径和CCFL数据卡

注意:就老数据卡组转换而言,需要阅读此节。

这些卡是选择性的。如果这卡是用来指定界面阻力计算用的接管水力直径,那么这直径值应该输入到字码W1中,在字码W2至4中应该输入任何允许的值。(将不会用到的)。如果这卡是用来指定CCFL模型,那么为了选择适当的CCFL模型,四个字码全部要输入。 W1(R) 接管水力直径D1(m,ft)。这个量是接管水力直径,用在CCFL关系式方程,和界面

阻力中,它必须大于等于零。如果进入零或用缺省值,那么这接管直径由2.0*(接管面积/π)0.5计算得到。

W2(R) 淹没关系形式,β。则用Wallis CCFL形式。如果为1,则用Kutateladze CCFL形式。

如果在零和1之间,则用Wallis和Kutateladze CCFL形式之间的Bankoff权重形式。这个数必须大于等于零且小于等于1。缺省值为零(Wallis形式)。 W3(R) 气体截距C。这个量是用在CCFL关系式中(当Hf

缺省值为1。

1/2

=0)气体截距,而且大于零,

W4(R) 斜率,m。这个量为用在CCFL关系式中的斜率,必须大于零,缺省值为1。 W5(R) 接管号。

A-7.7 分支、分离器,喷射混和器、透平或ECC混和器部件

一分支部件用BRANCH在CCC0000卡指明,蒸汽分离器以SEPARATR指明,喷射混和器以JETMIXER指明,透平用TURBINE指明,ECC混和器以ECCMIX指明。在接管参考符号里,部件进口代码为CCC000000,部件入口代码为CCC010000。部件的入口或出口可以有一个以上的接管与之相连。如果一端无接管,则这被认为是一个封闭端,通常只有分支部件才有一个以上的接管与一控制体端部相接。多重接管可以跟管壁墙面和单一控制体端面相连,尽管连接处理的很正确,但还会发出警告信号。限制跟分支不见多重连接,允许警告信息来指明可能的输入错误。如果多重接管跟一分支的一端相连,则每个接管应该用一面积突然变化来加以模拟。

一个分离器是个特殊的分支部件,它有三个节点。下面定义的N个必须为3,其它部件每有接管可以跟这部件相连。下面定义的N一定有N=1,2,3的值对接管情形,N=1为蒸汽出口,N=2为液体回落,N=3为分离器入口。蒸汽出口输入部分一定指分离器的出口(CCC010000),液体回落进入部分一定指分离器的入口(CCC000000)。为包括从蒸汽发生器下降腔到汽鼓这一支道,推荐用一旁通控制体。对这三个接管可以用平滑或突变的接管。为跟分离器的已知压降相匹配,适当地输入能量损失系数可能是需要的。推荐对所有三个接管都不用壅塞模型相连。蒸汽出口和液体回落接管应该用非均相选择。对这三个接管CCFL标识必须断开(f=0)。对分离器接管不用水平分层标识,因而应该设置为零(V=0)。

在分离器控制体里束棒界面摩擦标识必须断开(b=0)。在这分离器控制体里不用垂直分层型标识因而应置为零(V=0)。在分离器控制体里水程序包标识没有用到,因而也应置为零(p=0)。

一喷射混和器部件是一特殊的分支部件;有三个接管,象分离器一样方法给以编号。对于接管,N=1代表驱动,N=2代表吸入,N=3代表排出。进到驱动器和吸入接管的去侧一定是指喷射混和器的入口端(CCC000000),而由排出接管来侧一定是指喷射混和器的出口端(CCC010000)。为这个正确模拟一喷射泵,驱动和吸入的接管通流面积应该与控制体通流面积相等。对于所有三个接管CCFL标识必须断开(f=0)。水平分层标识对喷射混和器接管也不用,因而应该置为零(V=0)。在喷射混和器控制体时垂直分层模型标识没有用到,应该置为零(V=0)。而且水程序包标识没有用到,也应置为零(p=0)。

透平部件是一特殊的分支部件,需要另外输入来描述透平特性。一个简单的透平可以只用一个透平部件就行了。带蒸汽引出的多极透平可能需要几个透平部件。N必须等于1或2。对于接管,N=1模拟级的透平接管,N=2为蒸汽引出(流出)接管,必定为横向流。一次的蒸汽入口接管(N=1)是个正常接管二蒸汽引出线(N=2)是用一横流接管来模拟的。透平接管(N=1)必须是唯一进口接管,而且还有一个唯一出口接管(另一个部件的部件。蒸汽入口接管 (N=1)去侧一定是指这透平控制体的入口端(CCC000000)。目前存在一个限制(将来要去除的)即上游(正常流向)控制体和接管在竖直上一定是前面的控制体和接管,对第一级透平来说,必须有一个人造透平部件在其前面(即同效率透平h=0)。在人造透平上游的控制体和接管在竖直上不必是前面的控制体和接管。这人造透平的惯量和摩擦应该输入,它比正常透平小一些。(这个限制在将来也要去掉)。水平分层标识必须断开(V=0)。

如果几个透平部件串联起来,那么壅塞标识应该在第一个部件保留(C=0),而对其它部件应该断开(C=1)。进口和出口接管都应该选用平滑接管(a=0)。入口与出口接管必须输入为均相接管(h=2)。如果蒸汽引出(流出)接管存在,那么它必定是一个横向流接管(S=1或2或3)。CCFL标识对两种接管都必须断开(f=0)。在透平控制体束棒界面摩擦标识也必须断开(b=0)。垂直分层模型标识在透平控制体不用,因此应该置为零(V=0)。水物性程序包标识在透平控制体里也不用,因而也应该置为零(p=0)。

ECC混和器(ECCMIX)部件是一个特殊分支部件,它要求带有一定编号秩序的三个接管,ECC混和器的物理内容是一个冷端或任何其它的水平管,集中在ECC注入碘位置周围。这接管长度应该等于管内径的3倍(如果系统的实际安排允许的话)。第一号接管(编号最小的接管)必须是ECC连接点。在有些方向这根喷射混和器部件的驱动接管相类似。第二号接管(编号比第一号高的接管)应该是在正常操作下这个部件流动入口。接管1和2之间的几何夹角是必须要输入的一个量,它将在以后详细制定。第三个或排出接管是通过这段管段流动正常出口。接管1和2的去侧一定指ECC混和的入口端(CCC000000),而排出接管的来侧一定指ECC混和器出口端(CCC010000)。沿一根管子可以考虑由两个或几个ECCMIX部件,它们可以直接连接,或者期间通过接管连接。

对ECC混和器在CCC0000卡上这部件标识字码应该是ECCMIX。这个字码引导程序用蒸汽冷凝和ECC混和器用特定的流动工况图和特定边界面传热包。 A-7.7.1 分支部件、分离器,喷射混和器、透平或ECC混和器信息卡

W1(I) 接管数,NJ。NJ是部件的输入数据中所描述的接管数,它必须等于或大于零且小于等

于10个。对SEPARATR JETMIXER和ECCMIX部件这接管号必须为3,对于透平部件,这个数必须为1或2。对分支部件并非所有接管向分支部件的接管都必须随这个部件输入来加以描述,NJ也不一定等于接到分支部件接管的总数。在单一接管,时间相关接管,泵,分离器,喷射混合器和其他分支部件所描述的接管都可以跟这分支部件相连。

W2(I) 初始条件控制字码。这个字码是选择性的,如果不存在,则CCCN201 卡上的第一、第

二个字码是接管初始速度,如为零,则就假定初始状态速度。如果为非零,则就假定初始状态质量流量。 A-7.7.2 CCC0101至CCC0109卡,分支分离器,喷射混合器,透平或ECC混合控制几何卡。 这个卡式分支分离器,喷射混合器,透平或ECC混合器部件所要求的。9个字码可以输入在一张或击掌卡上卡片号不必依次相连。 W1(R) 控制体流通面积m2,ft2。 W2(R) 控制体长度(m,ft)。

。程序要求容积等于控制体流通面积乘以长度(W2=W1 *W2)。W3(R) 控制体容积(m3,ft3)

三个量中至少有二个不能为零。如果其中之一个为零,则其值由其他两个算得。如果这些字码都不为零,则容积必须等于面积乘以长度,其相对误差在0.000001之内。

W4(R) 方位角(度),这个角度绝对值必须小于等于360度,且限定为一个位置量。这个量在

计算中没有用到,而是标定用来可能的自动作用节点流程图的。

W5(R) 倾角(度),这个角度的绝对值一定小于等于90度,零角度表示水平,正角表示一个

向上的倾斜,即入口处于最低位置。这个角度在界面阻力计算中要用到。对ECCMIX,允许斜角小于±15度。其他任何值都认为是输入差错。

W6(R) 高度变化(m,ft)。正值表示高度增加。这个量的绝对值必须小于等于控制体长度。如

果垂直角朝向为零,则这个量也定为零,如果垂直角非零,那么这个量也一定非零,且与其符号相同。

W7(R) 壁面粗糙度(m,ft)。 W8(R) 水力直径(m,ft)。如果为零,水利直径由下式算得:2.0*(控制体面积/π)0.5。程序

要校核管子粗糙度是否小于水力直径的一半。

W9(I) 控制体控制标识,这个字码取组合格式pvbfe。

数字p指定水物性程序包用不用到。p=0指名控制体要用这个水物性程序包,

p=1指定控制体不用这个水物性程序包。当模拟稳压器时推荐用水物性程序包。这个数字BRANCH和ECCMIX部件也是用到,对SEPARATR,JETMIXER,TURBINE部件,为个数字没有用到,因而应该输入为零,大编辑将印p=1。

数字v指定垂直分层模型是否用到。v=0指定控制体要用垂直分层模型,v=1指定不用垂直分层模型。当模拟稳压器推荐用垂直分层模型。这个数字BRANCH部件也要用到。对SEPARATR,JETMIXER,TURBINE部件,为个数字没有用到,因而应该输入为零,大编辑将印v=1。

数字b指定要用到的界面摩擦模型,b=0意味着要用管内界面摩擦模型,b=1意味着要用束棒界面摩擦模型,这个数字只用于分支部件。对SEPARATR,JETMIXER,ECCMIX和TURBINE部件,不用此数字,因而应该置零。(大编辑将印b=0。

数字f指定壁面摩擦是否要计算。f=0指定控制体壁面摩擦效应要加以计算,f=1指定控制体壁面摩擦效应不加以计算。对于分离器程序将置f=1壁面摩擦将不计算。

数字e指定时用平衡态模型还是非平衡态模型,e=0指定要用非平衡(不相等的温度)态模型计算,而e=1指定要用平衡(相等温度)态模型计算。平衡态控制体不应跟非平衡控制体相连。提供平衡态选择只是为了跟其他程序加以比较用。

A-7.7.3 CCC0200卡,分支,分离器,喷射混合器,透平或ECC混合器控制体初始工况。 这个卡是分支,分离器,喷射混合器,透平或ECC混合部件所要求的。

W1(I) 控制字码。这个字码组合格式εbt。数字ε指定流体。ε=0为缺省流体,ε=1指定水,ε=2

指定D2O,ε=3指定氢,缺省流体是通过120至129卡为水力学系统是指的流体或在这个水力学系统另外控制体重控制字码设定的流体。120至129卡或这些控制字码设置的流体类型必须是一致的,即不能指定不同的流体。如果120至129卡不进入且所有控制字码用缺省值ε=0,那么就假定为水这种流体。

数字b指定硼是否存在。b=0指定控制体不包含硼,b=1指定在其他所要求的水力学信息之后要进入硼浓度,它以硼量比液态水量表示(可以为零)。

数字t指定其后字码如何被用来确定初始热力学状态。进入t=0至3指定单组分(蒸汽/水)。进入t=4至6允许标定双组分(蒸汽/水和不可冷凝气体)。

,蒸汽比如果t=0,其后四个字码理解为压力(Pa,1bf/in2)液态比内能(J/kg,Btu/1b)

内能(J/kg,Btu/1b)和汽相空泡份额。这些量可以理解为非平衡态也可理解为平衡态,它取决于控制体标识,如果处于平衡态则要校核静态含气量。但是只用压力和内能来确定热力学状态。

如果t=1,其后两个字码理解为温度(K,°F)和平衡态下的含气量。

如果t=2,其后两个字码理解为压力(Pa,1bf/in2)和平衡态下的含气量。

。 如果t=3,其后两个字码理解为压力(Pa,1bf/in2)和平衡态下的温度(K,°F)

下面选择只用于输入不可冷凝状态。在任何情况下,确定含量值范围所用的准则为: 1.0E-9≤含汽量≤0.99999999属两相工况。含汽量<1.0E-9或含汽量>0.99999999属单相工况 不可冷凝工况选择为:

,温度(K,°F)和平衡态含汽量。用如果t=4,其后三个字码理解为压力(Pa,1bf/in2)

这种含汽量大于零且小于等于1.0的输入选择,将会得到饱和的不可冷凝工况,而且还要将温度限制在输入压力相应的饱和温度以下。置含汽量为零被用作一种标识,即要把控制体初始化到全部为不可冷凝工况(干不可冷凝工况)而不带温度限制。用这干不可冷凝工况选择将含汽量重新设置为1.0。

如果t=5 ,其后3个字码理解为温度(K,°F),平衡态含气量和不可冷凝含汽量。平衡态含汽量和不可冷凝含汽量被限制在1.0E-9至0.99999999之间。

如果t=6,其后5个字码理解为温度(K,°F),液体比内能,液态比内能(J/kg,Btu/1b),汽相比内能(J/kg,Btu/1b),汽相空泡份额和不可冷凝含汽量。汽相空泡份额和不可冷凝含汽量的组合在热力学上必须是一致的。如果不可冷凝含汽量设置为0.0,则不存在不可冷凝气体,输入处理就输入无不可冷凝那种处理类型。如果不可冷凝含汽量设置为1.0(纯不可冷凝),那么汽相空泡份额也一定为1.0。当汽相空泡份额和无不可冷凝含汽量都置为1.0时,控制体温度就要用输入的汽相比内能由不可冷凝能量方程算出来。

W2-W6(R) 第一个字码W1 里说明的那些量。取决于控制字码,可能要求2至5个量要输入。

只输入要求输入的那些量。如果硼浓度要输入的话,那么硼浓度要跟在蛇力学工况要求最后一个字码后面输入。 A-7.7.4 CCC0201卡,分支,分离器,喷射混合器,透平或ECC混合器接管几何卡。

如果NJ大于零时才要求这些卡。输入带有N的卡片,N等于1至9。每个卡片对应一个接管N=1至3一定能用于SEPARATR,JETMIXER和ECCMIX部件。对一分支部件,N不必一次相连,但是必须输入NJ卡片。第1至第6个字码的卡片格式列在下面,除了第四个数字用N而不用另外其他与A-7.4.1节单一接管几何卡的CCC0101卡的第一至第六个字码是完全一样的。对BRANCH,JETMIXER和TURBINE部件第7个字码没有用到。第7个字码是为SEPARATR和ECCMIX部件定义的。

W1(I) 来向部件的连接代码,这表示是一样的部件,接管坐标方向是从这个部件出来的。对

于跟一时间相关控制体的连接,连接代码为CCC000000,其中CCC是这时间相关控制体的部件号。可以用老的格式也可以用扩展的格式跟所有其他控制体相连。按老格式表示时如果连接是跟这个部件的入口侧,则用CCC000000,如果是跟控制体的出口侧相连,则用CCC010000。老格式中用W6来指定一个横向流连接,在扩展格式下,连接代码为CCCVV000N,此中CCC为部件号,VV为控制体号,N表明表面号。一个非零的N指定了扩展格式。N等于1和2分别指定控制体坐标方向的入口和出口表面。N和3至6指定横向流。目前横向流模型不要求入口出口方向,但在将来版本,N=5和6将指定第三个坐标轴方向的入口和出口表面。因为在扩展格式中横向流是直接指定的,因此第六个字码W6中的横向流标识在输入时被忽略了,但在输出编辑中要加以适当设置。注意,在处理一管部件的控制体时老格式和扩散格式之间在能力上有一个重要的区别。用老格式,连接只可能跟第一个管控制体的入口或横向流表面活着跟最后一个管控制体的出口或横向流表面。而用扩展格式,可以跟管部件任何控制体的任何表面进到连接。不管其输入格式如何,输出编辑用扩展的格式。

W2(I) 去向部件连接数代码。这个指定这样一个部件接管坐标方向终止于这个部件。见上述对

第一个字码W1的描述。

W3(R) 接管面积(m2,ft2),若为零,则面积就置为两个相邻的控制体最小的那个控制体面积。

对面积突变情形,接管面积必须等于或小于相邻控制体面积的最小值。对面积平滑变化的情形,没有什么限制。

W4(R) 正向中流动的能量损失系数。 W5(R) 反向流动的能量损失系数。

W6(I) 接管控制标识,这个字码取组合格式fvcahs。

数字f指定用于BRANCH部件。对SEPARATR,JETMIXER,ECCMIX和TDRBINE部件,这个数字没有用刀,因而应该置为零(大编辑输出将印f=0)。

数字v指定水平分层夹带/抽出选择。v=0意味着不用这个模型,v=1意味着一个朝向上的接管,v=2为一个朝向下的接管,v=3为一个中心侧位置接管。这个数字只用于BRANCH部件。对于SEPARATR,JETMIXER,ECCMIX和TURBINE部件,不用这个数

字,因此应该设置为零。

数字c指定壅塞模型选择,c=0意味着要用多壅塞模型,c=1表不用壅塞模型。 数字a指定面积变化选择,a=0表面平滑变化或没有变化,a=1表面积突变。 数字h指定非均相还是均相。h=0指定非均相(双速动量方程组)选择,h=2指定均相(单一速度方程),对均相选择(h=2),大编辑打印将印1。

数字s指定正常接管还是横向流管。这个数字用于BRANCH,SEPARATR和TURBINE部件。s=0指定一正常接管,s=1指定1个横向流接管及指明去向控制体是一个横向流控制体。s=2指定一横向流接管并指明束向控制体是一个横向流控制体。s=3指定一横向流接管且指明束,去向控制体是一个横向流控制体。对JETMIXER部件,这个数字没有用到,应该输入为零。

W7(R) 空泡份额限制(对SEPARATR部件)或角度(对ECCMIX部件)。这个字码只有

SEPARATR或ECCMIX部件才需要。对SEPARATR,这个字码为空泡份额限制。对蒸汽出口接管(N=1),这个量(VOVER)是蒸汽空泡份额,高于这个值表示从蒸汽出口出来的流动是纯净的蒸汽,如果这个字码不存在,则用缺省值0.5。对液体回落接管,这个量(VUNDER)是液相空泡份额,高于这个值,则这流体回落出来的流动是纯粹液体。如果这个字码不存在,则用缺省值0.5。对分离器入口这个字码有用到。对于ECCMIX,这个字码为角度,是ECC注入线和主管系轴之间的夹角ψ(或者管1和2

之间的夹角)。这个角必须在0和180o之间。如果不存在,则就假定对ECC管连接为90o。

A-7.7.5 CCCN110卡,分支、分离器、混合器,透平或ECC混合器与接管直径,和CCFL数据卡

注意:从老数据的转换意义上来说,需要阅读此节。

这些卡是选择性的。如果这个卡将用于指定界面阻力计算用的接管水力直径,那么在第一个字码W1应该输入直径,在第2至4个字码里应该输入四个字码来适当选择CCFL模型。

W1(R) 接管水力直径D1(m,ft)。这个量是用在CCFL关系式方程和界面阻力的接管水力直径。必

须大于等于0。如果为零或者用缺省值,则接管直径由2.0×(接管面积/π)0.5算得。 W2(R) 淹没关系形式,β。如果为零,则用Wallis的CCEL形式。如果为1,则用Kutntalaze的CCFL形式。如果在0和1之间则用Wallis和Kutateladze CCFL形式之间的Bankoff权重形式。这个数必须大于等于0且小于等于1。缺省值为0(Wallis形式)。

W3(R) 气体截距,c。这个量是用在CCFL关系式(当Hf1/2 =0)中与气体截距,必须大于0。

缺省为1。

W(4) 斜率,m。这个量是用在CCFL关系式中的倾率必须大于0,缺省值为1。

A-7.7.6 CCCN201卡 分支、分离器、喷射混合器、透平或ECC混合器接管的初始条件。

根据CCCN101卡所描述的NJ值,需要这些卡片。

W1(R) 初始液体速度或质量流量(速度m/s,ft/s,质量流量kg/s,1b/s)。 W2(R) 初始蒸汽速度或质量流量(速度m/s,ft/s,质量流量kg/s,1b/s)。 A-7.7.7 CCC0300卡,透平/轴几何卡

这个卡只应用于TURBINE部件。

W1(R) 透平级轴转速stage s haft speed(rad/s,rev/min)。这个速度等于在SHAFT轴部件所用的速

度。

W2(R) 在级组里转级的惯量,Ij(kgm2,1bft2)。

W3(R) 轴摩擦系数,fj(N.m.s,1bft.s),摩擦扭矩等于fiw。SHAFT部件要用这个摩擦扭矩。 W4(I) 透平级(stage)与之相连的轴部件号。

W5(I) 断开触发号。若为零,则透平始终跟轴相连。如果不为零,则当触发为假时透平跟轴相

连,当触发号为真时就断开。

W6(I) 排泄标识,目前,这还没有用到,因而可以忽略或置为零。 A-7.7.8 CCC0400卡,透平性能数据卡 这个卡是只用于TURBINE部件。 W(l) 透平类型

0――双排无脉动级组。 1――一般无脉动一反应级组 2――恒效率级组。

W2(R) 在效率最高设计点处的实际效率η。

W3(R) 实际反应份额,r。这就是在转动叶片系统里发生的焓减少份额。 W4(4) 平均级半径R(m,ft)。 A-7.8 阀接管部件

阀接管部件在CCC0000卡上用VALVE来表示。 A-7.8.1 CCC0101至CCC0109卡,阀接管几何卡

这个卡是阀接管部件所需要的。

Wl(I) 来向部件连接码。这指定这样一个部件,接管坐标方向是从这个部件出发。对跟一个时间

相关控制体的连接码为CCC000000,其中CCC为时间相关控制体部件号。可以用老格式或用扩展格式跟其他控制体相连。按老格式,如果连接是跟部件的入口侧相连则用CCC000000,如果是跟控制体的出口侧相连则用CCC010000。用老格式不可能指定一个横向流连接。按扩展格式,连接码为CCCVV000N,此中CCC为部件号,VV为控制体号,N指明表面号。一个非零的N就指定这是个扩展格式。N=1和2分别指定控制体坐标方向的进出口表面。N=3至6指定了横向流。目前横流横型还不要求进出口方向,但在将来版本中,N3至4将指定第二个坐标方向的进出口表面。N=5和6将指定第三坐标方向的进出口表面。因为横向流在扩展格式中是直接指定的,因而W6中横向流标识在输入时可以不顾(忽略),但是在输出编辑时要适当加以设置。注意在处理管部件拉制体时老格式和扩展格式之间能力上有一个重要的区别。用老格式,连接只可能限于跟第一个管控制体的入口或横向流表面或跟最后一个管控制体的出口或横向流表面,而用扩展格式,可以跟任何一个管控制体的任何表面相接,不管其输入格式如何输入,输出编辑用扩展格式。

W2(I) 去向控制体连接码,这指定这样一个部件,接管的坐标方向终止于这个部件,参见上述

W1的描述。

。这个量是阀门全开面积(释放阀情况除外)。对除了释放阀以外的阀,W3(R) 接管面积(m2,ft2)

如果这个面积输入为零,则面积就设置为相连接的控制体最小的那个面积。如果为非零,则就用这个面积。则于释放阀,这个量为阀进口(没印上 )口直径算得的面积此中进口直径项不能输入为零。如果这个面积和入口直径输入都为非零,则要用这面积而且必须跟

由入口直径算出的面积差额在1.0×105m2之内。然而,如果这个面积输入为非零,而入口直径输入为零,则入口直径就缺省为由这面积算得的直径。当指定用面积突然变化型时,那么面积必须小于或等于相邻接的控制体面积的最小面积。

W4(R) 正向流动能量损失系数。

W5(R) 反向流动能量损失系数。

W6(I) 接管控制标识,这个字码取组合格式fvcahs

数字f指定CCFL选择,f=0意味着不用CCFL模型,f=1表示要用CCFL模型。 数字c指定壅塞模型选择,c=0表要用壅塞模型,c=1表不用壅塞模型。

数字a指定面积变化选择,a=0表面积平滑变化或面积不变化。a=1表面积突变。对马达阀或伺服阀,可以选择其中之一输入。如果输入面积平滑变化那么必须输入Cv表,如果不输入Cv表,那么就必须输入面积突变的选择。对于其他阀,必须输入面积突变选择。

数字h指定非均相还是均相。h=0指定非均相(双速动量方程组)选择。h=2指定均相(单一速度动量方程)选择。对均相选择(h=2),大编辑打印将印出1。 数字s没有用到,应该输入为零,大编辑将印出s=0.

W7(R) 欠热排放系数,这个量只用于欠热壅塞流计算。这个量必须大于零,且小于等于2。如果

不存在,则设置为1.0。

W8(R) 两相排放系数,这个量只用于过热壅塞计算。这个量必须大于零;且小于等于2。如果不

存在,则设置为1.0。 A-7.8.2 CCC0110卡,阀接管直径和CCFL数据卡

注意:从老数据卡组转换来说,需要阅读此节。

这个卡片时选择性的,如果这个卡仅仅用来指定接管水力直径供界面阻力计算,那么在第一个字码里W1应进入直径,在第2至4个字码里进入任何允许的值(这不会用到的)。如果这卡用来指定CCFL模型,那么要进入四个字码来适当确定CCFL模型。

这是用在CCFL关系方程或界面阻力里的接管水力直径,必须>=0。W1(R) 接管水力直径Dl(m,ft),

如果进入零或用其缺省值,则接管水力直径由2.0*(接管面积/π)0..5计算得到。 如果为零,则用Wallis CCFL关系式,若为1,则用Kutateladze CCFLW2(R) 淹没关系式形式, β。形式。若在零于1之间,则用Wallis和Kutateladze形式之间的Bankoff权重,这个数必

须>=0且<=1。缺省值为0(Wallis形式)。

W3(R) 气体截距,c。这是在CCFL关系式(Hf1/2=0时)中的气体截距必须>0。缺省值为1。 W4(R) 斜率,m。这是用在CCFL关系式中的斜率,必须>0。缺省值为1。 A-7.8.3 CCC0201卡,阀接管初始条件

这卡时阀接管部件所要求的。

W1(I) 控制字码。若为零,则下面两个字码为速度,若为1,则下面两个字码为质量流量。 W2(R) 液相初始速度或质量流量、这个量是速度(m/s,ft/s)还是质量流量(kg/s,1b/s)取决于控

制字码。

W3(R) 汽相初始速度或质量。这个量是速度(m/s,ft/s)还是质量流量(kg/s,1b/s)取决于控制字

码。

W4(R) 界面速度(m/s,ft/s)。输入零。 A-7.8.4 CCC0300卡,阀类型卡,这个卡是指定阀类型所要求的。

W1(A) 阀类型。这个字码必须为下面所述类型里的一个:CHKVLV,止回阀,TRPVLV触发阀,

INRVLV惯性旋转止回阀,MTRVLV马达阀,SRVVLV伺服阀,RLFVLV释放阀。 A-7.8.5 CCC0301至CCC0399卡,阀数据和初始条件

这些卡是阀接管部件所要求的。允许有六种不同类型的阀门。下面字码可以放在一张或几张卡片上,卡片号不必依次相连,卡片格式取决于阀类型。 A-7.8.5.1 止回阀。

其行为象一个通断开关。如果这阀接通,那么全开,如果断开,则全关。

W1(I) 止回阀类型。对静压控制的止回阀(无迟滞)就进入+1。对静压/流量控制的止回阀(有

延迟效应),就进入0,对静压/动压控制的止回阀(有延迟效应)就进入-1。

W2(I) 止回阀初始位置。如果为零,则阀初始为开状态。若为1,则为闭状态。

。 W3(R) 关闭背压(Pa,1bf/in2)

W4(R) 泄漏率。这是当阀名义上关闭是泄漏面积占接管面积的份额。如果忽略或输入为零,那

么可能指定面积平滑变化或突变模型。如果输入非零,那么必定指定面积突变模型。 A-7.8.5.2 触发阀。

这个数必须是一个有效的触发号,如果触发为假,则阀关闭,触发为真则阀打开。 A-7.8.5.3 惯性阀。

其行为实际上阀面积随水动力,阀瓣惯量,动量和角加速度而变的。必须指定面积突变模型。 W1(I) 止锁选择。如果选择为零,则这阀可以重复开启和关闭。如果选择为1,则仅能打开或关

闭一次。

W2(I) 阀初始状态。如果为零,这阀初始状态是打开的。如果为1则初始是关闭的。

。 W3(R) 关闭背压(Pa,1bf/in2)

W4(R) 泄漏份额,当阀名义上关闭时,泄漏面积占接管面积的份额。 W5(R) 阀瓣初始角度(度)。阀瓣角度必须在W6和W7字码中指定的最小最大角之间。 W6(R) 最小角(度)。 W7(R) 最大角(度)。

。 W8(R) 阀活瓣的惯性矩(kgm2,1bft2)

W9(R) 初始角速度(rad/s)。

W10(R) 阀活瓣的力矩长度(m,ft)。 W11(R) 阀活瓣半径(m,ft)。 W12(R) 阀活瓣质量(kg,1b)。 A-7.8.5.4 马达阀。

其行为实际上阀面积按用户指定的两个模型其中一个方式随时间变化。用户还必须通过指定面积平滑变化还是突然变化模型选择阀水动力学损失模型。若选择面积平滑变化模型,那么还必须输入一张流量系数表如在A-7.8.5小节里所描述的(即CCC0400至CCC0499 CSUBV表)。如果选择面积突变模型,则不能输入流量系数表。 W1(I) 打开触发号

W2(I) 关闭触发号,打开和关闭触发号都必须为有效的触发号。当两个触发号为假时,则阀停留

在当前位置不动。当其中一个触发号失真时,则阀或开或关,取决于哪个触发号为真。如果两个触发号同时为真时,则瞬态就终止了。

。如果W5字码不输入,那么这个量就是阀开或关时一化的阀面积变化率。W3(R) 阀变化率(s-1)

如果W5字码输入,那么这个量时归一化的阀杆位置的变化率。这个字码必须大于零。

W4(R) 初始位置。这个数为归一化的初始阀面积或为归一化的初始阀杆位置,取决于W5字码。

这个量必须在0.0和1.0之间。

W5(I) 阀表号。如果这个字码忽略输入为零,则阀面积由阀变化率和触发来决定。如果这个字码

输入为非零,则阀杆位置由阀变化率和触发来定,且阀面积由包含归一化的阀面积对归一化的阀杆位置的一张总表来确定。总表输入在A-11.2(202TTTNN卡,总表数据)节讨论。对这个情形,归一化的阀杆位置输入为自变量值,归一化的阀面积输入为函数值。 A-7.8.5.5 伺服阀。

其行为跟马达阀描述的行为一样,只是阀面积位置是通过控制系统计算得到。控制系统的输入在A-14(205CCCNN或205CCCCN卡控制系统输入数据)里加以讨论。指定伺服阀水动力学损失的输入也跟马达阀完全一样。

W1(I) 控制变量号。指示的控制变量值就是或为归一化的阀面积,或为归一化的阀杆位置,取决

于W2字码是否输入。如果CSUBV表输入的话,则这控制变量还是该表的检索变置。

W2(I) 阀表号。如果这个字码不输入,则这控制变量值就是归一化的流通面积。如果输入,则这

控制变量值就是归一化的阀杆位置。由这个字码所指定的总表包含了一个归一化面积对归一化的阀杆位置表。总表输入跟马达阀总表输入完全一样。 A-7.8.5.6 释放阀。

阀面积变化考虑了水动力学及阀质量,动量和加速度。必须指定面积突变模型。

CCC0101和CCC0199卡上接管面积输入为阀入口面积。(见本手册第一卷参考文献中图55

。 中的面积AD)

W1(I) 阀初始条件。如果为零则阀初始值为关闭状态,若为1则为开状态。W2(R)入口直径(m,ft),这是阀入口内径。如果输入为零,则就缺省为CCC0101至CCC0109卡接管面积输入算得的直径,如果这个直径和接管面积都输入为非零,则需加小心,这些项输入要有足够大的数字以使面积符合在1.0×10-5m2之内。如果接管面积输入为零,那么这个这个直径必须输入为非零。这个项相当于本手册卷1,图55中DD。 W3(R) 阀座直径(m,ft)。要求非零输入。这项是阀座的外径。包括内部调节环的最小直径。这

个项还必须大于或等于入口直径。它相应于本手册第一卷图56中Ds。

W4(R) 阀门柱塞直径(m,ft)如果输入为零。则就缺省为阀座直径。这个项相当于本手册卷1

图55中的Dp。

W5(R) 阀门升程(m,ft),要求输入非零。它为全开位置时阀门柱塞在阀座上升起的距离。这

个项相当于本手册卷1图55中Xr。

W6(R) 内部调节环的最大外径(m,ft)。如果输入为零,则就缺省值为阀座直径,在那种情形

中W7(R)必须输入为零。如果输入非零,则其值必须大或等于阀座直径。如果输入大于阀座直径,则允许W7(R)输入非零。这个项相当于本手册第一卷图56中的Di。还参见说明W9(R)中的警告。

W7(R) 内部调节环外部台肩相对于阀座的高度。一个正为的非零输入时不允许的。

如果先前的W6(R)缺省或输入等于阀座直径,则要求输入为零。注意如果台肩比阀座低,那么这个距离为负值。这个项相应于本手册卷1图56中的Hi。还要参见说明W9(R)的警告。

。如果输入非零,则缺省为阀门柱塞直径,在这情形下,W8(R) 外部调节环的最小内径(m,ft)

W9(R)必须输入正的非零值。如果输入非零,则其值必定大于或等于阀门柱塞直径。只有这个直径大于阀门柱塞直径负的W9(R)输入才是允许的。这个项相应于本手册卷1图56中D。还须参见说明W9(R)的警告。

W9(R) 外部调节环内部底边相对于阀座的高度(m,ft)。这可输入为正值、零或负值。如果这

个输入为负值,那么先前的W8(R)必定大于阀柱直径。注意如果底边比阀座低,那么这个距离为负值。这个项相应于本手册卷1图56中的H。警告,这项和先前说过的项W6(R)、W7(R)和W8(R)的输入必须小心做以确保调节环的间隙为正值且非零,否则导致输入错误。

W10(R) 波纹管的平均直径(m,ft)。如果这项输入为零,则缺省为阀门柱塞直径,结果一个不

包含波纹管的模型,即阀门帽压曝露到大气中。这项相应于本手册卷1图55中的DB。

W11(R) 阀弹簧常数(N/m,1bf/ft)。若为正值,则要求输入非零值。这项相应于手册第一卷方

程657中的Ks。

W12(R)阀设置点压力(Pa,1bf/in2)要求输入非负值。这项被归结为本手册卷1方程657中的

KsX。

W13(R) 阀门柱塞、杆、弹簧、波纹管的质量(kg,1b)。要求输入非零值。这个合并的质量相

应于本手册卷1方程657中的Wm。

W14(R) 阀门阻尼系数(N,s/m,1bf.s/ft)。这项相应于本手册卷1方程667中的B。

。如果省略或输入为零,则缺省为标准的大气压。这项相W15(R) 波纹管内侧压力(Pa,1bf/in2)

应于卷1方程657和图55中的Pa。

W16(R) 初始阀杆位置。这是以总升起高度的份额来表示,如果W1(I)输入为1就要求输入,总

升起高度输入为W5(R)。

W17(R) 阀门柱塞初始速度(m/s,ft/s)。如果W1(I)输入为零,则这项必须为零或省略。这项相应

于本手册卷1图55中和方程657中的Vv。 A-7.8.6 CCC0400至CCC0499卡,阀CSUBV

CSUBV表只对马达和伺服阀才可以输入。如果输入CSUBV表,那么在阀接管几何卡(CCC0101至CCC0109卡)上必须标定面积平滑变化,倒过来,如果指定面积平滑变化模型,则必须输入CSUBV表。

CSUBV表包含正向和反向的流向系数随归一化的流动面积或归一化的阀杆位置的变化情况。或CSUBVA-7.8.6.1 CCC0400卡,因子。这个卡时选择性的。这因子适用于流通面积表中阀杆位置和流量系数的输入量。W1(R)归一化流通面积或归一化的阀杆位置因子。W2(R)流量系数因子。 A-7.8.6.1 CCC0401至CCC0499卡,表输入量,这表以三个字码一组输入。W1时通流面积或阀杆位置,必须时归一化的。

在CCC0400卡上的W1因子可以用于归一化的通流面积或阀杆位置。在任何一种情况里,隐含着如果阀全关,则归一化为零,如阀全开,则归一化项为零,如阀全开,则归一化项为1。可以输入零和1之间任何一个值。正向和反向流量系数分别W2和W3。程序内部通过共识K=2×Aj2/(RHO*CSUBV)的定义。为要用CSUBV表在CCC0101卡上W6里必须指定面积平滑变化。CSUBV只以英制单位输入。

W1(R) 归一化流动面积或归一化的阀杆位置。

。这CSUBV只以英制单位输入用7.598055E-7座位W2(R) 正向CSUBV(gal/[min.(1bf/in)20.5])

转因子转换到国际单位制SI。

W3(R) 反向的CSUBV(gal/[min.(1bf/in20.5])。 A-7.9 泵部件

泵部件在CCC0000卡上用PUMP指明。泵由一个控制体和两个接管组成,控制体每一端附一个接管。

A-7.9.1 CCC0101至CCC0107卡,泵控制体几何卡

这个卡是泵部件所要求的。7个字码可以在一张或几张卡输入,卡号不必依次相连。

。 W1(R) 控制体通流面积(m2,ft2)

W2(R) 控制体长度(m,ft)。

。程序要求,其容积等于控制体通流面积乘上长度(W3=W1×W2)。W3(R) 控制体容积(m3,ft3)

三个量W1、W2、W3中至少有两个量必须为非零,如果有一个量为零,则其值为由其他两个量算得。如果没有一个为零,则容积必须等于面积乘长度,相对误差在0.000001之内。

W4(R) 方位角(度),这个角的绝对值必须<=360o。这个量在计算中不用,而是标定用来可能自

动作节点流程图用。

W5(R) 倾角(度)。这个绝对值必须<=91o。0o角为水平,正角表向上倾斜,即出口比入口高。

这角用在界面阻力计算中。

W6(R) 高度变化(m,ft)。正值为标高度增加。这个量必须等于或小于控制体长度,如果垂直角

方向为零,则这个量必须为零。如果垂直角非零,那么这个量也非零,且与角同符号。

W7(I) 控制体控制标识,这个字码取组合格式pvbfe。

数字p没有用到,应该输入为零,大编辑输出将印p=1。 数字v没有用刀,应该输入为零,大编辑输出印v=1。 数字b没有用到,应该输入为零,大编辑输出印b=0。

数字f通常指定壁面摩擦要加以计算还是不用,对一个泵而言,不计算壁面摩擦,因为它计入在泵的归一化数据中了,大编辑打印将印f=1,这表明不置摩擦标识。

数字e指定是用非平衡状态还是用平衡态。e=1批定要用平衡态(相对温度)计算。平衡态控制体不应该跟非平衡态控制体相连,配备有平衡态选择只是为了跟其他程序作比较用。 A-7.9.2 CCC0108卡,泵入口(吸入)接管卡

这个卡是泵部件所要求的。

W1(I) 连接于入口侧的控制体代码。它指定这样的控制体,接管坐标方向由这个控制体出发的。

对跟一个时间相关控制体连接情形,其连接代码为CCC000000,其中CCC为时间相关体的部件号。跟其他控制体的连接可以用老格式或用扩展格式。按老的格式,如果是跟部件的入口侧相连,则用CCC000000,如果是跟控制体出口侧相连,则用CCC010000。按老的格式,要指定一个横向流连接是不可能的。接扩展格式,连接代码为CCCVV000N,其中CCC为部件号,VV为控制体号。N表示面号。一个非零的N指定扩展格式。N=1和2指定控制体坐标方向入口和出口表面。N=3至6指定横向流。目前横向流模型不要求进口出口方向,但是在将来版本里,N3和4指定第二个坐标方向的入口和出口面。N=5和6将指定第三个坐标方向的入口和出口面。因为在扩展格式中横向流是直接加以指定的,因此W6中横流标识在输入时忽略不顾的,而在输入编辑中要加以适当设置。注意,在处理管部件控制体时老格式和扩展格式之间能力上有一个很重要的差别。用老格式,连接只可能限制于第一个管控制体的入口或横向流面,或者最后管控制体的出口或横向流面。而用扩展格式,可以跟任何管控制体任何管控制体的任何面进行连接。输出编辑不管输入格式如何用扩展格式。

W2(R) 接管面积(㎡,ft2)若为零,则置面积为相邻控制体最小的那个控制体面积。如果面积突

然变化,则接管面积必须等于或小于相邻控制体面积最小的那个面积。如果面积平滑变化,则没有什么限制。

W3(R) 正向流动能量损失系数。

W4(R) 反向流动能量损失系数。

W5(I) 接管控制标识。这个字码取组合格式pvcahs。数字f指定CCFL选f=0意指不用CCFL

模型。f=1表示要用CCFL模型。数字v没有用到,应该输入为零(v=0)。数字c指定壅塞选择。c=0表示要用壅塞模型,c=1表示不用壅塞模型。数字a指定面积变化选择。a=0表示面积平滑变化或不变。a=1表示面积突变。数字h指定非均相或均相。h=0指定非均相(双速动量方程)选择,h=2指定均相(单一速度动量方程)选择,对均相选择(h=2),大编辑打印将印1。数字s没有用到,应该输入为零。 A-7.9.3 CCC0109卡,泵出口(排出)接管卡

这个卡是泵部件所要求的。这个卡的格式跟CCC0108卡完全相同,只是用出口接管的。 A-7.9.4 CCC0110卡,泵入口(吸入)接管直径和CCFL数据卡。

注意:就老根据组卡转换而言,需阅读此节。

这卡是选择性的。如果用这个卡只指定界面阻力计算用的接管水力直径,在第一个字码W1中应该进入这直径,第2至第4个字码W2-W4中应该进入任何允许的值(这些值不会用到)。如果这卡是用来指定CCFL模型,那么为了合适选择CCFL模型,四个字码全要输入。

。这是用在CCFL关系式和界面阻力的接管水力直径,必须大于W1(R) 接管水力直径Dj(m,ft)

等于零。如果输入零或用缺省值,则接管直径就由下式算得:2.0*(接管面积/p)0.5 W2(R) 淹没关系形式,b。如果为零,则用Wallis CCFL型式。若为1,则用Kutateladze CCFL型式。如果在零和1之间,则用Wallis和KatateladzeCCFL型式之间Bankoff权重,这个量必须大于等于0且小于等于1。缺省值为0(Wallis型式)。

W3(R) 气体截距,C。这是CCFL关系式(当H1/2=0时)所用的气体截距,必须大于零。缺省

值为1。

W4(R) 斜率,m。这是CCFL关系式中所用的斜率,必须大于零。缺省值为1。 A-7.9.5 CCC0111卡,泵出口(排出)接管直径和CCFL数据卡

这个卡时选择性的。如果这个卡打算用来指定界面阻力算用的接管那么在W1中应该输入这个直径,在W2-W4中应该输入任何允许的值(不会用到)。如果这个卡用作为指定CCFL模型,则为了合适选择CCFL模型,四个字码全要输入。这个卡的格式跟CCFL卡完全相同,只是数据要用出口接管的。

A-7.9.6 CCC0200卡,泵控制体初始条件

这个卡时泵部件所要求的。

W1(I) 控制字码。这个字码取组合格式εbt。

,ε=3指定氢数字ε指定流体,ε=0为缺省流体。ε=1指定水,ε=2指定D2O(重水)

气。缺省流体是用120至129卡为水动力学系统或这水动力学系统中另一控制体的这个控制字码设置的流体。在120至129卡上设置的流体类型或这些控制字码设置的流体类型必须一致,即不能指定不用流体。如果120至129卡不输入且所有控制字码用缺省值ε=0,那么就假定水为流体。

数字b指定硼存在不存在。数字b=0指定控制体不包含硼,b=1指定硼浓度,硼量比液态水量,在其他要求的热力学信息输入之后输入。

数字t指定下列字码是如何用来确定初始热力学状态。输入t=0至3,指定单组分(蒸